# The following synthetic makes an assessment on the current configuration of the METIS decontamination heaters. # # The nominal Relaybox LCL configuration is for both of them to be ON. # # Only one of the two METIS decontamination heaters should be switched on at any time. # # The synthetic will return an integer status based on the discovered configuration. Note that this is used as an applicability value # for the OOL sets on the temperatures of the respective thermal lines. # # 0 : NOMINAL OFF ==> Both LCLs On or Off, Both Heaters OFF # 1 : NOMINAL ON ==> Both LCLs On, Only one Heater On # 2 : INCORRECT CONF ==> ((One LCL on, one LCL off) AND (All HTR configurations)) OR ((All LCL configurations) AND (Both HTRs on)) # # # Define return values VAR_NOMINAL_OFF := 0; VAR_NOMINAL_ON := 1; VAR_INCORRECT_CONF := 2; # Get TTR CPDU SCV status VAR_TTR_CPDU_A_STATUS := NCSG0740.eng; VAR_TTR_CPDU_B_STATUS := NCSG0750.eng; # Get PCDU SCV status VAR_PCDU_A_STATUS := NCSG0PC0.eng; VAR_PCDU_B_STATUS := NCSG0PD0.eng; # If PCDU-A is active if (VAR_PCDU_A_STATUS == "ON_ON_ON") then # Get Relaybox LCLs statuses from PCDU-A VAR_DEC_LCL_1_ST := NPWD0050.eng; VAR_DEC_LCL_2_ST := NPWD0010.eng; else # Get Relaybox LCLs statuses from PCDU-B VAR_DEC_LCL_1_ST := NPWT0050.eng; VAR_DEC_LCL_2_ST := NPWT0010.eng; endif; # If TTR CPDU A is ON if (VAR_TTR_CPDU_A_STATUS == "ON_ON_ON") then # Get METIS Nominal and Redundant heater statuses from TTR CPDU-A VAR_METIS_HTR_A := NCD2Z00S.eng; VAR_METIS_HTR_B := NCD2Z017.eng; else # Get METIS Nominal and Redundant heater statuses from TTR CPDU-B VAR_METIS_HTR_A := NCD2Z02S.eng; VAR_METIS_HTR_B := NCD2Z037.eng; endif; # # Check status of LCLs # if ((VAR_DEC_LCL_1_ST == "ON") land (VAR_DEC_LCL_2_ST == "ON")) then # # Both Relaybox LCLs are ON # # Check status of METIS Prime and Redundant heaters # if ((VAR_METIS_HTR_A == "On") land (VAR_METIS_HTR_B == "On")) then # Both heaters are ON ==> INCORRECT CONF return(VAR_INCORRECT_CONF); endif; if ((VAR_METIS_HTR_A == "Off") land (VAR_METIS_HTR_B == "Off")) then # Both heaters are OFF ==> NOMINAL OFF return(VAR_NOMINAL_OFF); endif; # One heater is ON and the other OFF ==> NOMINAL ON return(VAR_NOMINAL_ON); endif; if ((VAR_DEC_LCL_1_ST == "OFF") land (VAR_DEC_LCL_2_ST == "OFF")) then # # Both Relaybox LCLs are OFF # # Check status of METIS Prime and Redundant heaters # if ((VAR_METIS_HTR_A == "Off") land (VAR_METIS_HTR_B == "Off")) then # Both heaters are OFF ==> NOMINAL OFF configuration return(VAR_NOMINAL_OFF); endif; # At least on heater is ON ==> INCORRECT CONF return(VAR_INCORRECT_CONF); endif; # # One Relaybox LCL is ON and the other is OFF ==> INCORRECT CONF # return(VAR_INCORRECT_CONF);