Check for CDF files in /data/zdata_1/spdf_archive/public/pub/test/AUTO-INGEST/solar_orbiter/ingest_dev/SOLAR-ORBITER/SWA/masters Checking 20 file(s). Checking solo_l1_swa-eas1-nm3d_00000000_v01.cdf...0 0 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l1_swa-eas1-nm3d_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Attribute 'Mods' should be named 'MODS'. Logical_file_id should be 'solo_l1_swa-eas1-nmc_00000000_v01'. It is 'solo_L1_swa-eas1-NM3D_20200615T144838-20200615T175338_V01'. TEXT global attribute is missing. (Named attribute not found in this CDF.) Discipline global attribute is missing. (Named attribute not found in this CDF.) solo_l1_swa-eas1-nm3d_00000000_v01.cdf: FAILED variable checks. Errors: Variable EPOCH: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL value of '-9223372036854775807' is non-standard. The recommended value is 'ISTP FILLVAL (-9223372036854775808)'. FAILED variable checks. Errors: Variable SCET: DEPEND_0 attribute is missing. Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_upper: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_lower: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_upper: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_lower: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS1_ENERGY: DEPEND_0 attribute is missing. FAILED variable checks. Errors: Variable SWA_EAS1_ENERGY_delta_upper: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS1_ENERGY_delta_lower: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS1_Data: SWA_EAS1_ENERGY DEPEND_0 attribute is missing. LABL_PTR_3 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) FAILED variable checks. Errors: Variable SWA_EAS1_Mode: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FILLVAL value of '4294967294' is non-standard. The recommended value is '4294967295'. FAILED variable checks. Errors: Variable SWA_EAS1_Full3DValidity: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FILLVAL value of '4294967294' is non-standard. The recommended value is '4294967295'. Width of I3 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS_ElevationValidity: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FILLVAL value of '4294967294' is non-standard. The recommended value is '4294967295'. Width of I3 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS1_DataValidity: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FILLVAL value of '4294967294' is non-standard. The recommended value is '4294967295'. Width of I3 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable EAS1_TO_SRF: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable QUALITY_FLAG: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FORMAT and FORM_PTR attribute value is missing. Checking solo_l1_swa-eas1-ssc_00000000_v01.cdf...0 1 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l1_swa-eas1-ssc_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Attribute 'Mods' should be named 'MODS'. Logical_file_id should be 'solo_l1_swa-eas1-ssc_00000000_v01'. It is 'solo_L1_swa-eas1-SSc_20200615T144926-20200615T175246_V01'. TEXT global attribute is missing. (Named attribute not found in this CDF.) Discipline global attribute is missing. (Named attribute not found in this CDF.) solo_l1_swa-eas1-ssc_00000000_v01.cdf: FAILED variable checks. Errors: Variable EPOCH: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL value of '-9223372036854775807' is non-standard. The recommended value is 'ISTP FILLVAL (-9223372036854775808)'. FAILED variable checks. Errors: Variable SCET: DEPEND_0 attribute is missing. VALIDMIN data type 'CDF_EPOCH' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMAX data type 'CDF_EPOCH' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS1_SS_Data: LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) FAILED variable checks. Errors: Variable SWA_EAS1_Mode: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FILLVAL value of '4294967294' is non-standard. The recommended value is '4294967295'. FORMAT 'f14.4' is invalid for a CDF_UINT4 type variable FAILED variable checks. Errors: Variable SWA_EAS1_Energy: DEPEND_0 attribute is missing. FAILED variable checks. Errors: Variable SWA_EAS1_dataValidity: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FILLVAL value of '4294967294' is non-standard. The recommended value is '4294967295'. FORMAT 'f14.4' is invalid for a CDF_UINT4 type variable FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_upper: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_lower: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_upper: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_lower: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable EAS1_TO_SRF: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable QUALITY_FLAG: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FORMAT and FORM_PTR attribute value is missing. Checking solo_l1_swa-eas2-nm3d_00000000_v01.cdf...0 2 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l1_swa-eas2-nm3d_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Attribute 'Mods' should be named 'MODS'. Logical_file_id should be 'solo_l1_swa-eas2-nmc_00000000_v01'. It is 'solo_L1_swa-eas2-NM3D_20200615T144838-20200615T175338_V01'. TEXT global attribute is missing. (Named attribute not found in this CDF.) Discipline global attribute is missing. (Named attribute not found in this CDF.) solo_l1_swa-eas2-nm3d_00000000_v01.cdf: FAILED variable checks. Errors: Variable EPOCH: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL value of '-9223372036854775807' is non-standard. The recommended value is 'ISTP FILLVAL (-9223372036854775808)'. FAILED variable checks. Errors: Variable SCET: DEPEND_0 attribute is missing. Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_upper: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_lower: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_upper: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_lower: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS2_ENERGY: DEPEND_0 attribute is missing. FAILED variable checks. Errors: Variable SWA_EAS2_ENERGY_delta_upper: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS2_ENERGY_delta_lower: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS2_Data: SWA_EAS2_ENERGY DEPEND_0 attribute is missing. LABL_PTR_3 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) FAILED variable checks. Errors: Variable SWA_EAS2_Mode: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FILLVAL value of '4294967294' is non-standard. The recommended value is '4294967295'. FAILED variable checks. Errors: Variable SWA_EAS2_Full3DValidity: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FILLVAL value of '4294967294' is non-standard. The recommended value is '4294967295'. Width of I3 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS_ElevationValidity: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FILLVAL value of '4294967294' is non-standard. The recommended value is '4294967295'. Width of I3 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS2_DataValidity: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FILLVAL value of '4294967294' is non-standard. The recommended value is '4294967295'. Width of I3 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable EAS2_TO_SRF: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable QUALITY_FLAG: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FORMAT and FORM_PTR attribute value is missing. Checking solo_l1_swa-eas2-ssc_00000000_v01.cdf...0 3 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l1_swa-eas2-ssc_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Attribute 'Mods' should be named 'MODS'. Logical_file_id should be 'solo_l1_swa-eas2-ssc_00000000_v01'. It is 'solo_L1_swa-eas2-SSc_20200615T144926-20200615T175246_V01'. TEXT global attribute is missing. (Named attribute not found in this CDF.) Discipline global attribute is missing. (Named attribute not found in this CDF.) solo_l1_swa-eas2-ssc_00000000_v01.cdf: FAILED variable checks. Errors: Variable EPOCH: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL value of '-9223372036854775807' is non-standard. The recommended value is 'ISTP FILLVAL (-9223372036854775808)'. FAILED variable checks. Errors: Variable SCET: VALIDMIN data type 'CDF_REAL8' does not match variable data type 'CDF_EPOCH'. The automatic conversion could not be done. VALIDMAX data type 'CDF_REAL8' does not match variable data type 'CDF_EPOCH'. The automatic conversion could not be done. FAILED variable checks. Errors: Variable SWA_EAS2_SS_Data: LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) FAILED variable checks. Errors: Variable SWA_EAS2_Mode: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FILLVAL value of '4294967294' is non-standard. The recommended value is '4294967295'. FORMAT 'f14.4' is invalid for a CDF_UINT4 type variable FAILED variable checks. Errors: Variable SWA_EAS2_Energy: DEPEND_0 attribute is missing. FAILED variable checks. Errors: Variable SWA_EAS2_dataValidity: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FILLVAL value of '4294967294' is non-standard. The recommended value is '4294967295'. FORMAT 'f14.4' is invalid for a CDF_UINT4 type variable FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_upper: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_lower: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_upper: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_lower: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable EAS2_TO_SRF: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable QUALITY_FLAG: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FORMAT and FORM_PTR attribute value is missing. Checking solo_l1_swa-eas-onbpartmoms_00000000_v01.cdf...0 4 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l1_swa-eas-onbpartmoms_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Attribute 'Mods' should be named 'MODS'. Logical_file_id should be 'solo_l1_swa-eas-partmoms_00000000_v01'. It is 'solo_L1_swa-eas-OnbPartMoms_20200615T144826-20200615T175346_V01'. TEXT global attribute is missing. (Named attribute not found in this CDF.) Discipline global attribute is missing. (Named attribute not found in this CDF.) solo_l1_swa-eas-onbpartmoms_00000000_v01.cdf: FAILED variable checks. Errors: Variable EPOCH: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL value of '-9223372036854775807' is non-standard. The recommended value is 'ISTP FILLVAL (-9223372036854775808)'. FAILED variable checks. Errors: Variable EPOCH_1: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL value of '-9223372036854775807' is non-standard. The recommended value is 'ISTP FILLVAL (-9223372036854775808)'. FAILED variable checks. Errors: Variable SCET: DEPEND_0 attribute is missing. Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SCET_1: DEPEND_0 attribute is missing. Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS1_dataValidity: SWA_EAS1_dataValidity's 0 dimension has a size of 1. Sizes < 2 are likely to be a problem. UNITS (and UNIT_PTR) attribute is missing. FAILED variable checks. Errors: Variable SWA_EAS2_dataValidity: SWA_EAS2_dataValidity's 0 dimension has a size of 1. Sizes < 2 are likely to be a problem. UNITS (and UNIT_PTR) attribute is missing. FAILED variable checks. Errors: Variable SWA_EAS_SumEAS1: SWA_EAS_SumEAS1's 0 dimension has a size of 1. Sizes < 2 are likely to be a problem. UNITS (and UNIT_PTR) attribute is missing. FAILED variable checks. Errors: Variable SWA_EAS_SumEAS2: SWA_EAS_SumEAS2's 0 dimension has a size of 1. Sizes < 2 are likely to be a problem. UNITS (and UNIT_PTR) attribute is missing. FAILED variable checks. Errors: Variable SWA_EAS_SCPotential: SWA_EAS_SCPotential's 0 dimension has a size of 1. Sizes < 2 are likely to be a problem. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS1_SumMoms: UNITS (and UNIT_PTR) attribute is missing. FAILED variable checks. Errors: Variable SWA_EAS2_SumMoms: UNITS (and UNIT_PTR) attribute is missing. FAILED variable checks. Errors: Variable SWA_EAS1_only_Low_Ene_N: SWA_EAS1_only_Low_Ene_N's 0 dimension has a size of 1. Sizes < 2 are likely to be a problem. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS1_only_Low_Ene_V: LABL_PTR_1 does not point to a metadata variable. FAILED variable checks. Errors: Variable SWA_EAS1_only_Low_Ene_P: DEPEND_1 attribute is missing. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS1_only_Low_Ene_H: LABL_PTR_1 does not point to a metadata variable. Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS1_only_Core_Halo_N: SWA_EAS1_only_Core_Halo_N's 0 dimension has a size of 1. Sizes < 2 are likely to be a problem. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS1_only_Core_Halo_V: LABL_PTR_1 does not point to a metadata variable. FAILED variable checks. Errors: Variable SWA_EAS1_only_Core_Halo_P: DEPEND_1 attribute is missing. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS1_only_Core_Halo_H: LABL_PTR_1 does not point to a metadata variable. Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS1_only_Strahl_N: SWA_EAS1_only_Strahl_N's 0 dimension has a size of 1. Sizes < 2 are likely to be a problem. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS1_only_Strahl_V: LABL_PTR_1 does not point to a metadata variable. FAILED variable checks. Errors: Variable SWA_EAS1_only_Strahl_P: DEPEND_1 attribute is missing. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS1_only_Strahl_H: LABL_PTR_1 does not point to a metadata variable. Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS2_only_Low_Ene_N: SWA_EAS2_only_Low_Ene_N's 0 dimension has a size of 1. Sizes < 2 are likely to be a problem. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS2_only_Low_Ene_V: LABL_PTR_1 does not point to a metadata variable. FAILED variable checks. Errors: Variable SWA_EAS2_only_Low_Ene_P: DEPEND_1 attribute is missing. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS2_only_Low_Ene_H: LABL_PTR_1 does not point to a metadata variable. Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS2_only_Core_Halo_N: SWA_EAS2_only_Core_Halo_N's 0 dimension has a size of 1. Sizes < 2 are likely to be a problem. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS2_only_Core_Halo_V: LABL_PTR_1 does not point to a metadata variable. FAILED variable checks. Errors: Variable SWA_EAS2_only_Core_Halo_P: DEPEND_1 attribute is missing. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS2_only_Core_Halo_H: LABL_PTR_1 does not point to a metadata variable. Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS2_only_Strahl_N: SWA_EAS2_only_Strahl_N's 0 dimension has a size of 1. Sizes < 2 are likely to be a problem. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS2_only_Strahl_V: LABL_PTR_1 does not point to a metadata variable. FAILED variable checks. Errors: Variable SWA_EAS2_only_Strahl_P: DEPEND_1 attribute is missing. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS2_only_Strahl_H: LABL_PTR_1 does not point to a metadata variable. Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS1_overlap_Low_Ene_N: SWA_EAS1_overlap_Low_Ene_N's 0 dimension has a size of 1. Sizes < 2 are likely to be a problem. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS1_overlap_Low_Ene_V: LABL_PTR_1 does not point to a metadata variable. FAILED variable checks. Errors: Variable SWA_EAS1_overlap_Low_Ene_P: DEPEND_1 attribute is missing. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS1_overlap_Low_Ene_H: LABL_PTR_1 does not point to a metadata variable. Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS1_overlap_Core_Halo_N: SWA_EAS1_overlap_Core_Halo_N's 0 dimension has a size of 1. Sizes < 2 are likely to be a problem. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS1_overlap_Core_Halo_V: LABL_PTR_1 does not point to a metadata variable. FAILED variable checks. Errors: Variable SWA_EAS1_overlap_Core_Halo_P: DEPEND_1 attribute is missing. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS1_overlap_Core_Halo_H: LABL_PTR_1 does not point to a metadata variable. Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS1_overlap_Strahl_N: SWA_EAS1_overlap_Strahl_N's 0 dimension has a size of 1. Sizes < 2 are likely to be a problem. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS1_overlap_Strahl_V: LABL_PTR_1 does not point to a metadata variable. FAILED variable checks. Errors: Variable SWA_EAS1_overlap_Strahl_P: DEPEND_1 attribute is missing. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS1_overlap_Strahl_H: LABL_PTR_1 does not point to a metadata variable. Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS2_overlap_Low_Ene_N: SWA_EAS2_overlap_Low_Ene_N's 0 dimension has a size of 1. Sizes < 2 are likely to be a problem. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS2_overlap_Low_Ene_V: LABL_PTR_1 does not point to a metadata variable. FAILED variable checks. Errors: Variable SWA_EAS2_overlap_Low_Ene_P: DEPEND_1 attribute is missing. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS2_overlap_Low_Ene_H: LABL_PTR_1 does not point to a metadata variable. Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS2_overlap_Core_Halo_N: SWA_EAS2_overlap_Core_Halo_N's 0 dimension has a size of 1. Sizes < 2 are likely to be a problem. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS2_overlap_Core_Halo_V: LABL_PTR_1 does not point to a metadata variable. FAILED variable checks. Errors: Variable SWA_EAS2_overlap_Core_Halo_P: DEPEND_1 attribute is missing. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS2_overlap_Core_Halo_H: LABL_PTR_1 does not point to a metadata variable. Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS2_overlap_Strahl_N: SWA_EAS2_overlap_Strahl_N's 0 dimension has a size of 1. Sizes < 2 are likely to be a problem. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS2_overlap_Strahl_V: LABL_PTR_1 does not point to a metadata variable. FAILED variable checks. Errors: Variable SWA_EAS2_overlap_Strahl_P: DEPEND_1 attribute is missing. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS2_overlap_Strahl_H: LABL_PTR_1 does not point to a metadata variable. Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable EAS_VEL_LABEL: EAS_VEL_LABEL's 0 dimension has a size of 3 and dimension variance of NOVARY. VAR_TYPE value 'meta_data' is not a valid value. FAILED variable checks. Errors: Variable EAS_HFlux_LABEL: EAS_HFlux_LABEL's 0 dimension has a size of 3 and dimension variance of NOVARY. VAR_TYPE value 'meta_data' is not a valid value. FAILED variable checks. Errors: Variable REP_VEL_LABEL: REP_VEL_LABEL's 0 dimension has a size of 3 and dimension variance of NOVARY. UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable REP_HFlux_LABEL: REP_HFlux_LABEL's 0 dimension has a size of 3 and dimension variance of NOVARY. UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable REP_EAS_PRES_1: REP_EAS_PRES_1's 0 dimension has a size of 3 and dimension variance of NOVARY. UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable REP_EAS_PRES_2: REP_EAS_PRES_2's 0 dimension has a size of 3 and dimension variance of NOVARY. UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable EAS1_TO_SRF: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable EAS2_TO_SRF: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (No such entry for specified attribute.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable QUALITY_FLAG: QUALITY_FLAG's 0 dimension has a size of 1. Sizes < 2 are likely to be a problem. UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. VALIDMIN entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable QUALITY_FLAG_1: QUALITY_FLAG_1's 0 dimension has a size of 1. Sizes < 2 are likely to be a problem. UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. VALIDMIN entry is missing. (No such entry for specified attribute.) Checking solo_l1_swa-eas-padc_00000000_v01.cdf...0 5 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l1_swa-eas-padc_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Attribute 'Mods' should be named 'MODS'. Logical_file_id should be 'solo_l1_swa-eas-padc_00000000_v01'. It is 'solo_L1_swa-eas-padc_20200616T090001-20200616T100000_V01'. TEXT global attribute is missing. (Named attribute not found in this CDF.) Discipline global attribute is missing. (Named attribute not found in this CDF.) solo_l1_swa-eas-padc_00000000_v01.cdf: FAILED variable checks. Errors: Variable EPOCH: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL value of '-9223372036854775807' is non-standard. The recommended value is 'ISTP FILLVAL (-9223372036854775808)'. FAILED variable checks. Errors: Variable SCET: DEPEND_0 attribute is missing. VALIDMIN data type 'CDF_UINT1' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. Width of F14 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS_BM_Data: DISPLAY_TYPE attribute value 'Spectrogram' is not all lower case. SWA_EAS_ENERGY DEPEND_0 attribute is missing. SWA_EAS_ELEVATION DEPEND_0 attribute is missing. LABL_PTR_3 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN data type 'CDF_UINT1' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMAX data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION: DEPEND_0 attribute is missing. FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_upper: DEPEND_0 attribute is missing. LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FILLVAL entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_lower: DEPEND_0 attribute is missing. LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FILLVAL entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_upper: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_lower: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_ENERGY: DEPEND_0 attribute is missing. FAILED variable checks. Errors: Variable SWA_EAS_ENERGY_delta_upper: DEPEND_0 attribute is missing. LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FILLVAL entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_ENERGY_delta_lower: DEPEND_0 attribute is missing. LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FILLVAL entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_Mode: DEPEND_0 attribute is missing. VALIDMIN data type 'CDF_REAL8' does not match variable data type 'CDF_UINT4'. The automatic conversion could not be done. VALIDMAX data type 'CDF_REAL8' does not match variable data type 'CDF_UINT4'. The automatic conversion could not be done. FILLVAL data type 'CDF_REAL8' does not match variable data type 'CDF_UINT4'. The automatic conversion could not be done. FILLVAL value of '-1.0E31' is non-standard. The recommended value is '4294967295'. FORMAT 'f14.4' is invalid for a CDF_UINT4 type variable FAILED variable checks. Errors: Variable SWA_EAS_Validity: DEPEND_0 attribute is missing. VALIDMIN data type 'CDF_UINT1' does not match variable data type 'CDF_UINT4'. The automatic conversion could not be done. VALIDMAX data type 'CDF_UINT2' does not match variable data type 'CDF_UINT4'. The automatic conversion could not be done. FILLVAL data type 'CDF_REAL8' does not match variable data type 'CDF_UINT4'. The automatic conversion could not be done. FILLVAL value of '-1.0E31' is non-standard. The recommended value is '4294967295'. FORMAT 'f14.3' is invalid for a CDF_UINT4 type variable FAILED variable checks. Errors: Variable SWA_EAS_EasUsed: DEPEND_0 attribute is missing. VALIDMIN data type 'CDF_UINT1' does not match variable data type 'CDF_UINT4'. The automatic conversion could not be done. VALIDMAX data type 'CDF_UINT2' does not match variable data type 'CDF_UINT4'. The automatic conversion could not be done. FILLVAL value of '2282270756' is non-standard. The recommended value is '4294967295'. Width of I1 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SWA_EAS_ElevationUsed: DEPEND_0 attribute is missing. VALIDMIN data type 'CDF_UINT1' does not match variable data type 'CDF_UINT4'. The automatic conversion could not be done. VALIDMAX data type 'CDF_UINT2' does not match variable data type 'CDF_UINT4'. The automatic conversion could not be done. FILLVAL data type 'CDF_REAL8' does not match variable data type 'CDF_UINT4'. The automatic conversion could not be done. FILLVAL value of '-1.0E31' is non-standard. The recommended value is '4294967295'. FORMAT 'f14.3' is invalid for a CDF_UINT4 type variable FAILED variable checks. Errors: Variable SWA_EAS_MagDataUsed: DISPLAY_TYPE error: invalid display type 'time' DEPEND_1 attribute is missing. FAILED variable checks. Errors: Variable SWA_EAS_MagDataValidity: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FILLVAL value of '2282270756' is non-standard. The recommended value is '4294967295'. FAILED variable checks. Errors: Variable EAS_TO_SRF: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FILLVAL entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable EAS_TO_MAG: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FILLVAL entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable QUALITY_FLAG: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. Checking solo_l1_swa-his-pha_00000000_v01.cdf...0 6 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Column solo_l1_swa-his-pha_00000000_v01.cdf: FAILED global attribute check. Errors: Logical_file_id should be 'solo_swa-his_pha_l1_00000000_v00'. It is 'solo_L1_swa-his-pha_20200310_V00'. solo_l1_swa-his-pha_00000000_v01.cdf: Checking solo_l1_swa-his-sensorrates_00000000_v01.cdf...0 7 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Column solo_l1_swa-his-sensorrates_00000000_v01.cdf: FAILED global attribute check. Errors: Logical_file_id should be 'solo_swa-his_sensor_rates_l1_00000000_v00'. It is 'solo_L1_swa-his-sensorrates_20200310_V00'. solo_l1_swa-his-sensorrates_00000000_v01.cdf: Checking solo_l1_swa-pas-3d_00000000_v01.cdf...0 8 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l1_swa-pas-3d_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Logical_file_id should be 'solo_l1_swa-pas_00000000_v01'. It is 'solo_L1_swa-pas-3d_20200706_V01'. TEXT has no entries. solo_l1_swa-pas-3d_00000000_v01.cdf: FAILED variable checks. Errors: Variable Duration: DEPEND_0 attribute is missing. FORMAT and FORM_PTR attribute value is missing. FAILED variable checks. Errors: Variable CCSDS_time: VALIDMIN data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMAX data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMIN >= VALIDMAX FILLVAL data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. FILLVAL value of '0' is non-standard. The recommended value is '-1.0E31'. FAILED variable checks. Errors: Variable SCET: VALIDMIN data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMAX data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMIN >= VALIDMAX FILLVAL data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. FILLVAL value of '0' is non-standard. The recommended value is '-1.0E31'. FAILED variable checks. Errors: Variable SOURCE: Width of I1 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable COUNTS: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) Checking solo_l1_swa-pas-cal_00000000_v01.cdf...0 9 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l1_swa-pas-cal_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Logical_file_id should be 'solo_l1_swa-pas_00000000_v01'. It is 'solo_L1_swa-pas-cal_20200706_V01'. TEXT has no entries. solo_l1_swa-pas-cal_00000000_v01.cdf: FAILED variable checks. Errors: Variable CCSDS_time: VALIDMIN data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMAX data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMIN >= VALIDMAX FILLVAL data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. FILLVAL value of '0' is non-standard. The recommended value is '-1.0E31'. FAILED variable checks. Errors: Variable SCET: VALIDMIN data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMAX data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMIN >= VALIDMAX FILLVAL data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. FILLVAL value of '0' is non-standard. The recommended value is '-1.0E31'. FAILED variable checks. Errors: Variable SID_counter: UNITS (and UNIT_PTR) attribute is missing. FAILED variable checks. Errors: Variable START: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable FINAL: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable CURRENT: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable ACQUISITION: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable NB_ACQUISITION: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable STEP: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable MAX_EN: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable MAX_EL: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable MAX_CEM: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable MAX_COUNT: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) Checking solo_l1_swa-pas-mom_00000000_v01.cdf...0 10 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l1_swa-pas-mom_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Logical_file_id should be 'so_null_swa-pas_00000000_v01'. It is 'solo_L1_swa-pas-mom_20200706_V01'. Data_type has no entries. TEXT has no entries. Mission_group has no entries. solo_l1_swa-pas-mom_00000000_v01.cdf: FAILED variable checks. Errors: Variable CCSDS_time: VALIDMIN data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMAX data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMIN >= VALIDMAX FILLVAL data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. FILLVAL value of '0' is non-standard. The recommended value is '-1.0E31'. FAILED variable checks. Errors: Variable SCET: VALIDMIN data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMAX data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMIN >= VALIDMAX FILLVAL data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. FILLVAL value of '0' is non-standard. The recommended value is '-1.0E31'. FAILED variable checks. Errors: Variable sample: FILLVAL value of '-32767' is non-standard. The recommended value is '-32768'. FAILED variable checks. Errors: Variable validity: VALIDMIN data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. FILLVAL value of '254' is non-standard. The recommended value is '255'. FAILED variable checks. Errors: Variable sum_PAS: VALIDMIN data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. FAILED variable checks. Errors: Variable data_validity_flag: VALIDMIN data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. FAILED variable checks. Errors: Variable density: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable velocity: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable pressure: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable temperature: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) Checking solo_l2_swa-eas1-ss-def_00000000_v01.cdf...0 11 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l2_swa-eas1-ss-def_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Attribute 'Mods' should be named 'MODS'. Logical_file_id should be 'solo_l2_swa-eas1-ss-def_00000000_v01'. It is 'solo_L2_swa-eas1-ss-def_20200615T144926-20200615T175246_V01'. TEXT global attribute is missing. (Named attribute not found in this CDF.) Discipline global attribute is missing. (Named attribute not found in this CDF.) solo_l2_swa-eas1-ss-def_00000000_v01.cdf: FAILED variable checks. Errors: Variable EPOCH: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL value of '-9223372036854775807' is non-standard. The recommended value is 'ISTP FILLVAL (-9223372036854775808)'. FAILED variable checks. Errors: Variable SWA_EAS1_SS_Data: LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) FAILED variable checks. Errors: Variable SWA_EAS1_Energy: DEPEND_0 attribute is missing. FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_upper: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_lower: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_upper: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_lower: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable EAS1_TO_SRF: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable EAS1_TO_RTN: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable QUALITY_FLAG: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FORMAT and FORM_PTR attribute value is missing. Checking solo_l2_swa-eas1-ss-dnf_00000000_v01.cdf...0 12 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l2_swa-eas1-ss-dnf_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Attribute 'Mods' should be named 'MODS'. Logical_file_id should be 'solo_l2_swa-eas1-ss-dnf_00000000_v01'. It is 'solo_L2_swa-eas1-ss-dnf_20200615T144926-20200615T175246_V01'. TEXT global attribute is missing. (Named attribute not found in this CDF.) Discipline global attribute is missing. (Named attribute not found in this CDF.) solo_l2_swa-eas1-ss-dnf_00000000_v01.cdf: FAILED variable checks. Errors: Variable EPOCH: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL value of '-9223372036854775807' is non-standard. The recommended value is 'ISTP FILLVAL (-9223372036854775808)'. FAILED variable checks. Errors: Variable SWA_EAS1_SS_Data: LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) FAILED variable checks. Errors: Variable SWA_EAS1_Energy: DEPEND_0 attribute is missing. FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_upper: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_lower: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_upper: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_lower: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable EAS1_TO_SRF: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable EAS1_TO_RTN: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable QUALITY_FLAG: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FORMAT and FORM_PTR attribute value is missing. Checking solo_l2_swa-eas1-ss-psd_00000000_v01.cdf...0 13 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l2_swa-eas1-ss-psd_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Attribute 'Mods' should be named 'MODS'. Logical_file_id should be 'solo_l2_swa-eas1-ss-psd_00000000_v01'. It is 'solo_L2_swa-eas1-ss-psd_20200615T144926-20200615T175246_V01'. TEXT global attribute is missing. (Named attribute not found in this CDF.) Discipline global attribute is missing. (Named attribute not found in this CDF.) solo_l2_swa-eas1-ss-psd_00000000_v01.cdf: FAILED variable checks. Errors: Variable EPOCH: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL value of '-9223372036854775807' is non-standard. The recommended value is 'ISTP FILLVAL (-9223372036854775808)'. FAILED variable checks. Errors: Variable SWA_EAS1_SS_Data: LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) FAILED variable checks. Errors: Variable SWA_EAS1_Energy: DEPEND_0 attribute is missing. FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_upper: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_lower: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_upper: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_lower: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable EAS1_TO_SRF: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable EAS1_TO_RTN: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable QUALITY_FLAG: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FORMAT and FORM_PTR attribute value is missing. Checking solo_l2_swa-eas2-ss-def_00000000_v01.cdf...0 14 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l2_swa-eas2-ss-def_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Attribute 'Mods' should be named 'MODS'. Logical_file_id should be 'solo_l2_swa-eas2-ss-def_00000000_v01'. It is 'solo_L2_swa-eas2-ss-def_20200615T144926-20200615T175246_V01'. TEXT global attribute is missing. (Named attribute not found in this CDF.) Discipline global attribute is missing. (Named attribute not found in this CDF.) solo_l2_swa-eas2-ss-def_00000000_v01.cdf: FAILED variable checks. Errors: Variable EPOCH: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL value of '-9223372036854775807' is non-standard. The recommended value is 'ISTP FILLVAL (-9223372036854775808)'. FAILED variable checks. Errors: Variable SWA_EAS2_SS_Data: LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) FAILED variable checks. Errors: Variable SWA_EAS2_Energy: DEPEND_0 attribute is missing. FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_upper: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_lower: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_upper: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_lower: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable EAS2_TO_SRF: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable EAS2_TO_RTN: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable QUALITY_FLAG: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FORMAT and FORM_PTR attribute value is missing. Checking solo_l2_swa-eas2-ss-dnf_00000000_v01.cdf...0 15 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l2_swa-eas2-ss-dnf_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Attribute 'Mods' should be named 'MODS'. Logical_file_id should be 'solo_l2_swa-eas2-ss-dnf_00000000_v01'. It is 'solo_L2_swa-eas2-ss-dnf_20200615T144926-20200615T175246_V01'. TEXT global attribute is missing. (Named attribute not found in this CDF.) Discipline global attribute is missing. (Named attribute not found in this CDF.) solo_l2_swa-eas2-ss-dnf_00000000_v01.cdf: FAILED variable checks. Errors: Variable EPOCH: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL value of '-9223372036854775807' is non-standard. The recommended value is 'ISTP FILLVAL (-9223372036854775808)'. FAILED variable checks. Errors: Variable SWA_EAS2_SS_Data: LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) FAILED variable checks. Errors: Variable SWA_EAS2_Energy: DEPEND_0 attribute is missing. FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_upper: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_lower: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_upper: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_lower: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable EAS2_TO_SRF: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable EAS2_TO_RTN: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable QUALITY_FLAG: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FORMAT and FORM_PTR attribute value is missing. Checking solo_l2_swa-eas2-ss-psd_00000000_v01.cdf...0 16 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l2_swa-eas2-ss-psd_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Attribute 'Mods' should be named 'MODS'. Logical_file_id should be 'solo_l2_swa-eas2-ss-psd_00000000_v01'. It is 'solo_L2_swa-eas2-ss-psd_20200615T144926-20200615T175246_V01'. TEXT global attribute is missing. (Named attribute not found in this CDF.) Discipline global attribute is missing. (Named attribute not found in this CDF.) solo_l2_swa-eas2-ss-psd_00000000_v01.cdf: FAILED variable checks. Errors: Variable EPOCH: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL value of '-9223372036854775807' is non-standard. The recommended value is 'ISTP FILLVAL (-9223372036854775808)'. FAILED variable checks. Errors: Variable SWA_EAS2_SS_Data: LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) FAILED variable checks. Errors: Variable SWA_EAS2_Energy: DEPEND_0 attribute is missing. FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_upper: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_ELEVATION_delta_lower: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_upper: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable SWA_EAS_AZIMUTH_delta_lower: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable EAS2_TO_SRF: UNITS (and UNIT_PTR) attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable EAS2_TO_RTN: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable QUALITY_FLAG: UNITS (and UNIT_PTR) attribute is missing. DEPEND_0 attribute is missing. FORMAT and FORM_PTR attribute value is missing. Checking solo_l2_swa-pas-eflux_00000000_v01.cdf...0 17 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l2_swa-pas-eflux_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Attribute 'Text' should be named 'TEXT'. Logical_file_id should be 'solo_l2_swa-pas_00000000_v01'. It is 'solo_L2_swa-pas-eflux_20200706_V01'. TEXT global attribute is missing. (Named attribute not found in this CDF.) solo_l2_swa-pas-eflux_00000000_v01.cdf: FAILED variable checks. Errors: Variable Epoch: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FAILED variable checks. Errors: Variable Half_interval: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_REAL4'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_REAL4'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_REAL4'. The automatic conversion could not be done. FILLVAL value of '-1' is non-standard. The recommended value is '-1.0E31'. Width of F4 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable eflux: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) VALIDMIN data type 'CDF_UINT2' does not match variable data type 'CDF_REAL4'. The automatic conversion could not be done. Checking solo_l2_swa-pas-grnd-mom_00000000_v01.cdf...0 18 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l2_swa-pas-grnd-mom_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Attribute 'Text' should be named 'TEXT'. Logical_file_id should be 'solo_l2_swa-pas_00000000_v01'. It is 'solo_L2_swa-pas-grnd-mom_20200706_V01'. TEXT global attribute is missing. (Named attribute not found in this CDF.) solo_l2_swa-pas-grnd-mom_00000000_v01.cdf: FAILED variable checks. Errors: Variable Half_interval: Width of F4 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SCET: FILLVAL data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. FILLVAL value of '4294967295' is non-standard. The recommended value is '-1.0E31'. FAILED variable checks. Errors: Variable validity: VALIDMIN data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. FAILED variable checks. Errors: Variable N: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable V_SRF: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable V_RTN: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable P_SRF: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable P_RTN: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable TxTyTz_SRF: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable TxTyTz_RTN: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable T: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable V_SOLO_RTN: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FILLVAL data type 'CDF_CHAR' does not match variable data type 'CDF_FLOAT'. The automatic conversion could not be done. Checking solo_l2_swa-pas-vdf_00000000_v01.cdf...0 19 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l2_swa-pas-vdf_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Attribute 'Text' should be named 'TEXT'. Logical_file_id should be 'solo_l2_swa-pas_00000000_v01'. It is 'solo_L2_swa-pas-vdf_20200706_V01'. TEXT global attribute is missing. (Named attribute not found in this CDF.) solo_l2_swa-pas-vdf_00000000_v01.cdf: FAILED variable checks. Errors: Variable Epoch: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FAILED variable checks. Errors: Variable Half_interval: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_REAL4'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_REAL4'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_REAL4'. The automatic conversion could not be done. FILLVAL value of '-1' is non-standard. The recommended value is '-1.0E31'. Width of F4 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable PAS_to_RTN: VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable vdf: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable Elevation_correction: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) FORMAT and FORM_PTR attribute value is missing. FAILED variable checks. Errors: Variable Full_elevation: LABL_PTR_3 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) FORMAT and FORM_PTR attribute value is missing. FAILED variable checks. Errors: Variable Full_azimuth: LABL_PTR_3 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) FORMAT and FORM_PTR attribute value is missing. nPassed = 0 nFailed = 20