Checking solo_l1_swa-pas-3d_00000000_v01.cdf...0 8 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l1_swa-pas-3d_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Logical_file_id should be 'solo_l1_swa-pas_00000000_v01'. It is 'solo_L1_swa-pas-3d_20200706_V01'. TEXT has no entries. solo_l1_swa-pas-3d_00000000_v01.cdf: FAILED variable checks. Errors: Variable Duration: DEPEND_0 attribute is missing. FORMAT and FORM_PTR attribute value is missing. FAILED variable checks. Errors: Variable CCSDS_time: VALIDMIN data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMAX data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMIN >= VALIDMAX FILLVAL data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. FILLVAL value of '0' is non-standard. The recommended value is '-1.0E31'. FAILED variable checks. Errors: Variable SCET: VALIDMIN data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMAX data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMIN >= VALIDMAX FILLVAL data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. FILLVAL value of '0' is non-standard. The recommended value is '-1.0E31'. FAILED variable checks. Errors: Variable SOURCE: Width of I1 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable COUNTS: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) Checking solo_l1_swa-pas-cal_00000000_v01.cdf...0 9 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l1_swa-pas-cal_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Logical_file_id should be 'solo_l1_swa-pas_00000000_v01'. It is 'solo_L1_swa-pas-cal_20200706_V01'. TEXT has no entries. solo_l1_swa-pas-cal_00000000_v01.cdf: FAILED variable checks. Errors: Variable CCSDS_time: VALIDMIN data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMAX data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMIN >= VALIDMAX FILLVAL data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. FILLVAL value of '0' is non-standard. The recommended value is '-1.0E31'. FAILED variable checks. Errors: Variable SCET: VALIDMIN data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMAX data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMIN >= VALIDMAX FILLVAL data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. FILLVAL value of '0' is non-standard. The recommended value is '-1.0E31'. FAILED variable checks. Errors: Variable SID_counter: UNITS (and UNIT_PTR) attribute is missing. FAILED variable checks. Errors: Variable START: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable FINAL: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable CURRENT: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable ACQUISITION: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable NB_ACQUISITION: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable STEP: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable MAX_EN: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable MAX_EL: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable MAX_CEM: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable MAX_COUNT: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) Checking solo_l1_swa-pas-mom_00000000_v01.cdf...0 10 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l1_swa-pas-mom_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Logical_file_id should be 'so_null_swa-pas_00000000_v01'. It is 'solo_L1_swa-pas-mom_20200706_V01'. Data_type has no entries. TEXT has no entries. Mission_group has no entries. solo_l1_swa-pas-mom_00000000_v01.cdf: FAILED variable checks. Errors: Variable CCSDS_time: VALIDMIN data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMAX data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMIN >= VALIDMAX FILLVAL data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. FILLVAL value of '0' is non-standard. The recommended value is '-1.0E31'. FAILED variable checks. Errors: Variable SCET: VALIDMIN data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMAX data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. VALIDMIN >= VALIDMAX FILLVAL data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. FILLVAL value of '0' is non-standard. The recommended value is '-1.0E31'. FAILED variable checks. Errors: Variable sample: FILLVAL value of '-32767' is non-standard. The recommended value is '-32768'. FAILED variable checks. Errors: Variable validity: VALIDMIN data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. FILLVAL value of '254' is non-standard. The recommended value is '255'. FAILED variable checks. Errors: Variable sum_PAS: VALIDMIN data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. FAILED variable checks. Errors: Variable data_validity_flag: VALIDMIN data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. FAILED variable checks. Errors: Variable density: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable velocity: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable pressure: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable temperature: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) Checking solo_l2_swa-pas-eflux_00000000_v01.cdf...0 17 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l2_swa-pas-eflux_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Attribute 'Text' should be named 'TEXT'. Logical_file_id should be 'solo_l2_swa-pas_00000000_v01'. It is 'solo_L2_swa-pas-eflux_20200706_V01'. TEXT global attribute is missing. (Named attribute not found in this CDF.) solo_l2_swa-pas-eflux_00000000_v01.cdf: FAILED variable checks. Errors: Variable Epoch: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FAILED variable checks. Errors: Variable Half_interval: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_REAL4'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_REAL4'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_REAL4'. The automatic conversion could not be done. FILLVAL value of '-1' is non-standard. The recommended value is '-1.0E31'. Width of F4 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable eflux: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) VALIDMIN data type 'CDF_UINT2' does not match variable data type 'CDF_REAL4'. The automatic conversion could not be done. Checking solo_l2_swa-pas-grnd-mom_00000000_v01.cdf...0 18 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l2_swa-pas-grnd-mom_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Attribute 'Text' should be named 'TEXT'. Logical_file_id should be 'solo_l2_swa-pas_00000000_v01'. It is 'solo_L2_swa-pas-grnd-mom_20200706_V01'. TEXT global attribute is missing. (Named attribute not found in this CDF.) solo_l2_swa-pas-grnd-mom_00000000_v01.cdf: FAILED variable checks. Errors: Variable Half_interval: Width of F4 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable SCET: FILLVAL data type 'CDF_UINT4' does not match variable data type 'CDF_REAL8'. The automatic conversion could not be done. FILLVAL value of '4294967295' is non-standard. The recommended value is '-1.0E31'. FAILED variable checks. Errors: Variable validity: VALIDMIN data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT2' does not match variable data type 'CDF_UINT1'. The automatic conversion could not be done. FAILED variable checks. Errors: Variable N: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable V_SRF: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable V_RTN: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable P_SRF: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable P_RTN: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable TxTyTz_SRF: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable TxTyTz_RTN: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable T: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable V_SOLO_RTN: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FILLVAL data type 'CDF_CHAR' does not match variable data type 'CDF_FLOAT'. The automatic conversion could not be done. Checking solo_l2_swa-pas-vdf_00000000_v01.cdf...0 19 CDF File Version: 3.8.0 File Last Leap Second: 2017-01-01 Majority: Row solo_l2_swa-pas-vdf_00000000_v01.cdf: FAILED global attribute check. Errors: Warning: CDF is set for row major array variables and column major is recommended. Attribute 'Text' should be named 'TEXT'. Logical_file_id should be 'solo_l2_swa-pas_00000000_v01'. It is 'solo_L2_swa-pas-vdf_20200706_V01'. TEXT global attribute is missing. (Named attribute not found in this CDF.) solo_l2_swa-pas-vdf_00000000_v01.cdf: FAILED variable checks. Errors: Variable Epoch: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_TIME_TT2000'. The automatic conversion could not be done. FAILED variable checks. Errors: Variable Half_interval: VALIDMIN data type 'CDF_INT8' does not match variable data type 'CDF_REAL4'. The automatic conversion could not be done. VALIDMAX data type 'CDF_INT8' does not match variable data type 'CDF_REAL4'. The automatic conversion could not be done. FILLVAL data type 'CDF_INT8' does not match variable data type 'CDF_REAL4'. The automatic conversion could not be done. FILLVAL value of '-1' is non-standard. The recommended value is '-1.0E31'. Width of F4 FORMAT may be insufficient for values. Adjust FORMAT or VALIDMIN/VALIDMAX value to resolve. FAILED variable checks. Errors: Variable PAS_to_RTN: VALIDMIN entry is missing. (No such entry for specified attribute.) VALIDMAX entry is missing. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable vdf: Missing DISPLAY_TYPE attribute. (No such entry for specified attribute.) FAILED variable checks. Errors: Variable Elevation_correction: LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) FORMAT and FORM_PTR attribute value is missing. FAILED variable checks. Errors: Variable Full_elevation: LABL_PTR_3 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) FORMAT and FORM_PTR attribute value is missing. FAILED variable checks. Errors: Variable Full_azimuth: LABL_PTR_3 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_2 attribute is missing. (Named attribute not found in this CDF.) LABL_PTR_1 attribute is missing. (Named attribute not found in this CDF.) FORMAT and FORM_PTR attribute value is missing. nPassed = 0 nFailed = 20