PAS commissioning extra activities were operated on 2020/04/24
Some issues encountered :
Rejected TC
Two (three) PAS TC have been rejected :
2020-04-24T11:50:41.375 ERR -- 4 TC(203,140) ZIA58862
SWA TC PAS write Pre-Amp power Control register
2020-04-24T11:50:45.500 ERR -- 2 TC(203,137) ZIA58859
PAS Normal Power OFF
2020-04-24T15:04:56.501 ERR -- 2 TC(203,137) ZIA58859
PAS Normal Power OFF
We dont really understand why these TC have been rejected.
We receive for each one a TARF TM packet, SID = 43010 : SWA_TM_CMD_FACP_PAS_NPLAUS_TC,
that indicates a PAS Not Plausible TC error.
This error code is indicated in TARF data content : first 2 bytes = A802
We don’t understand the extend 2 bytes : CB 89
Documents
-
documents/2020-04-24/SWA_TC_Error.txt
Détail for the 3 TC rejections, extracted from TARF TM data
-
Full SWA TC report for 2020-04-24
FDIR event
An FDIR add been found on 2020/04/24 11:46
It concerns a PAS monitored HK paramaeter : PAS HK PLUS_24V_CEM_OUT
Value 4095 > FDIR Upper limit = 4094
Documents
-
Data dump of FDIR event data for this event
-
Full Data dump of all SWA Events data