PAS commissioning extra activities were operated on 2020/04/24

Some issues encountered :

Rejected TC

Two (three) PAS TC have been rejected :

2020-04-24T11:50:41.375 ERR                         --     4 TC(203,140)  ZIA58862
                                        SWA TC PAS write Pre-Amp power Control register
2020-04-24T11:50:45.500 ERR                         --     2 TC(203,137)  ZIA58859
                                        PAS Normal Power OFF
2020-04-24T15:04:56.501 ERR                         --     2 TC(203,137)  ZIA58859
                                        PAS Normal Power OFF

We dont really understand why these TC have been rejected.

We receive for each one a TARF TM packet, SID = 43010 : SWA_TM_CMD_FACP_PAS_NPLAUS_TC,
that indicates a PAS Not Plausible TC error.

This error code is indicated in TARF data content : first 2 bytes = A802

We don’t understand the extend 2 bytes : CB 89

Documents

FDIR event

An FDIR add been found on 2020/04/24 11:46

It concerns a PAS monitored HK paramaeter : PAS HK PLUS_24V_CEM_OUT

Value 4095 > FDIR Upper limit = 4094

Documents

Plot PAS currents and FDIR Events

documents/2020-04-24/FDIR.png