Issues for 2020-04-24 ===================== PAS commissioning extra activities were operated on 2020/04/24 Some issues encountered : == Rejected TC Two (three) PAS TC have been rejected : ---- 2020-04-24T11:50:41.375 ERR -- 4 TC(203,140) ZIA58862 SWA TC PAS write Pre-Amp power Control register 2020-04-24T11:50:45.500 ERR -- 2 TC(203,137) ZIA58859 PAS Normal Power OFF 2020-04-24T15:04:56.501 ERR -- 2 TC(203,137) ZIA58859 PAS Normal Power OFF ---- We dont really understand why these TC have been rejected. We receive for each one a TARF TM packet, SID = 43010 : SWA_TM_CMD_FACP_PAS_NPLAUS_TC, + that indicates a PAS Not Plausible TC error. This error code is indicated in TARF data content : first 2 bytes = A802 We don't understand the extend 2 bytes : CB 89 === Documents * link:documents/2020-04-24/SWA_TC_Error.txt[] + -- Détail for the 3 TC rejections, extracted from TARF TM data -- * link:/AUX/20200424/SWA_TC.txt[2020/04/24 SWA TC] + -- Full SWA TC report for 2020-04-24 -- == FDIR event An FDIR add been found on 2020/04/24 11:46 It concerns a PAS monitored HK paramaeter : PAS HK PLUS_24V_CEM_OUT Value 4095 > FDIR Upper limit = 4094 === Documents * link:documents/2020-04-24/FDIR_EVENT.txt[FDIR Event] + -- Data dump of FDIR event data for this event -- * link:/AUX/20200424/SWA_EVENT.txt[Full SWA Event report] + -- Full Data dump of all SWA Events data -- .Plot PAS currents and FDIR Events image:documents/2020-04-24/FDIR.png[width="100%"]