============================================== TELECOMMANDS for 2021-06-25 ============================================== TC acceptation and status TC execution and status Size Service ID Label --------------------------- --------------------------- ---- ----------- -------- ----- -- -- 2 TC(203,158) ZIA58944 SWA TC PAS stop science -- -- 22 TC(203,128) ZIA58850 SWA TC PAS enter in Calibration mode -- -- 20 TC(200,160) ZIA58726 SWA TC enter all sensor in Burst Mode 2021-06-25T17:02:00.662 OK 2021-06-25T17:02:00.662 OK 2 TC(200,148) ZIA58721 SWA TC disable Book Keeping 2021-06-25T17:02:10.662 OK 2021-06-25T17:02:10.662 OK 20 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2021-06-25T17:02:11.662 OK 2021-06-25T17:02:11.662 OK 20 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2021-06-25T17:02:12.662 OK 2021-06-25T17:02:12.662 OK 20 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2021-06-25T17:02:13.662 OK 2021-06-25T17:02:13.662 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2021-06-25T17:02:14.662 OK 2021-06-25T17:02:14.662 OK 10 TC(200,134) ZIA58707 SWA TC report configuration parameters 2021-06-25T17:02:20.662 OK 2021-06-25T17:02:20.662 OK 4 TC(200,147) ZIA58720 SWA TC enable Book Keeping 2021-06-25T17:02:30.662 OK 2021-06-25T17:02:31.287 OK 2 TC(200,153) ZIA58729 SWA TC DPU switch ON HIS 2021-06-25T17:02:31.662 ERR -- 2 TC(200,153) ZIA58729 SWA TC DPU switch ON HIS 2021-06-25T17:03:14.789 OK 2021-06-25T17:03:14.789 OK 10 TC(204,176) ZIA58931 SWA TC HIS Set housekeeping collection interval for spec. SID -- -- 6 TC(204,145) ZIA58917 SWA TC HIS change mode 2021-06-25T17:04:04.788 OK 2021-06-25T17:04:04.788 OK 6 TC(204,145) ZIA58917 SWA TC HIS change mode 2021-06-25T17:04:05.788 OK 2021-06-25T17:04:05.788 OK 10 TC(204,135) ZIA58907 SWA TC HIS enable/disable HV supplies 2021-06-25T17:04:06.788 OK 2021-06-25T17:04:06.788 OK 22 TC(204,136) ZIA58908 SWA TC HIS set DAC to absolute value. 2021-06-25T17:04:07.663 OK 2021-06-25T17:04:07.663 OK 4 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2021-06-25T17:07:30.788 OK 2021-06-25T17:07:30.788 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2021-06-25T17:07:31.788 OK 2021-06-25T17:07:31.788 OK 6 TC(204,141) ZIA58913 SWA TC HIS run the specified macro 2021-06-25T18:40:00.797 OK 2021-06-25T18:40:00.797 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2021-06-25T18:40:01.797 OK 2021-06-25T18:40:01.797 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2021-06-25T18:40:02.797 OK 2021-06-25T18:40:02.797 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2021-06-25T18:41:00.797 OK 2021-06-25T18:41:00.798 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2021-06-25T18:41:01.797 OK 2021-06-25T18:41:01.798 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2021-06-25T18:41:02.797 OK 2021-06-25T18:41:02.797 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2021-06-25T18:42:00.797 OK 2021-06-25T18:42:00.798 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2021-06-25T18:42:01.797 OK 2021-06-25T18:42:01.798 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2021-06-25T18:42:02.797 OK 2021-06-25T18:42:02.798 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2021-06-25T18:43:00.798 OK 2021-06-25T18:43:00.798 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2021-06-25T18:43:01.798 OK 2021-06-25T18:43:01.798 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2021-06-25T18:43:02.798 OK 2021-06-25T18:43:02.798 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2021-06-25T18:44:00.798 OK 2021-06-25T18:44:00.798 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2021-06-25T18:44:01.798 OK 2021-06-25T18:44:01.798 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2021-06-25T18:44:02.798 OK 2021-06-25T18:44:02.798 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2021-06-25T18:45:00.798 OK 2021-06-25T18:45:00.798 OK 6 TC(204,141) ZIA58913 SWA TC HIS run the specified macro 2021-06-25T19:00:10.674 OK 2021-06-25T19:00:10.674 OK 4 TC(200,162) ZIA58728 SWA TC modify the cadence of sci data generation 2021-06-25T19:00:20.674 OK 2021-06-25T19:00:20.674 OK 4 TC(201,172) ZIA58796 SWA TC EAS1 extract sthral energy 2021-06-25T19:00:30.674 OK 2021-06-25T19:00:30.674 OK 4 TC(202,172) ZIA58844 SWA TC EAS2 extract sthral energy 2021-06-25T19:00:40.674 OK 2021-06-25T19:00:40.674 OK 4 TC( 3, 5) ZIA58050 SWA TC enable HK report generation 2021-06-25T19:00:42.674 OK 2021-06-25T19:00:42.674 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-06-25T19:00:43.674 OK 2021-06-25T19:00:45.799 OK 2 TC(201,136) ZIA58760 SWA TC EAS1 Power ON 2021-06-25T19:20:50.676 OK 2021-06-25T19:20:51.176 OK 4 TC(201,135) ZIA58934 SWA TC EAS1 start service macro 2021-06-25T19:20:55.676 OK 2021-06-25T19:20:59.301 OK 2 TC(201,129) ZIA58753 SWA TC EAS1 enter in idle mode 2021-06-25T19:21:25.676 OK 2021-06-25T19:21:25.802 OK 2 TC(201,158) ZIA58782 SWA TC EAS1 HK data Request 2021-06-25T19:21:27.676 OK 2021-06-25T19:21:38.051 OK 2 TC(201,134) ZIA58758 SWA TC EAS1 HV Ramp UP 2021-06-25T19:21:57.677 OK 2021-06-25T19:21:57.803 OK 6 TC(201,152) ZIA58776 SWA TC EAS1 Write Master Control Register 2021-06-25T19:21:59.677 OK 2021-06-25T19:21:59.803 OK 6 TC(201,133) ZIA58757 SWA TC EAS1 Sensor Reset 2021-06-25T19:22:01.677 OK 2021-06-25T19:22:01.803 OK 14 TC(201,145) ZIA58769 SWA TC EAS1 Set Analizer Voltage Offsets 2021-06-25T19:22:03.677 OK 2021-06-25T19:22:03.803 OK 6 TC(201,142) ZIA58766 SWA TC EAS1 Set Hemisphere Voltage Ratio 2021-06-25T19:22:05.677 OK 2021-06-25T19:22:05.803 OK 6 TC(201,143) ZIA58767 SWA TC EAS1 Set Hemisphere High Voltage 2021-06-25T19:22:07.677 OK 2021-06-25T19:22:07.803 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2021-06-25T19:22:09.677 OK 2021-06-25T19:22:18.052 OK 66 TC(201,173) ZIA58797 SWA TC EAS1 set preamp control data 2021-06-25T19:22:19.677 OK 2021-06-25T19:22:19.803 OK 4 TC(201,160) ZIA58784 SWA TC EAS1 Set New HV for MCP 2021-06-25T19:22:49.676 OK 2021-06-25T19:22:49.676 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2021-06-25T19:22:51.676 OK 2021-06-25T19:22:51.676 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2021-06-25T19:23:00.677 OK 2021-06-25T19:23:00.677 OK 14 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2021-06-25T19:23:10.677 OK 2021-06-25T19:23:10.677 OK 4 TC( 3, 5) ZIA58050 SWA TC enable HK report generation 2021-06-25T19:23:12.677 OK 2021-06-25T19:23:12.677 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-06-25T19:23:13.677 OK 2021-06-25T19:23:15.802 OK 2 TC(202,136) ZIA58808 SWA TC EAS2 Power ON 2021-06-25T19:23:20.677 OK 2021-06-25T19:23:21.177 OK 4 TC(202,135) ZIA58936 SWA TC EAS2 start service macro 2021-06-25T19:23:25.677 OK 2021-06-25T19:23:29.302 OK 2 TC(202,129) ZIA58801 SWA TC EAS2 enter in idle mode 2021-06-25T19:23:55.677 OK 2021-06-25T19:23:55.803 OK 2 TC(202,158) ZIA58830 SWA TC EAS2 HK data Request 2021-06-25T19:23:57.677 OK 2021-06-25T19:24:08.052 OK 2 TC(202,134) ZIA58806 SWA TC EAS2 HV Ramp UP 2021-06-25T19:24:27.678 OK 2021-06-25T19:24:27.803 OK 6 TC(202,152) ZIA58824 SWA TC EAS2 Write Master Control Register 2021-06-25T19:24:29.678 OK 2021-06-25T19:24:29.803 OK 6 TC(202,133) ZIA58805 SWA TC EAS2 Sensor Reset 2021-06-25T19:24:31.678 OK 2021-06-25T19:24:31.803 OK 14 TC(202,145) ZIA58817 SWA TC EAS2 Set Analizer Voltage Offsets 2021-06-25T19:24:33.678 OK 2021-06-25T19:24:33.803 OK 6 TC(202,142) ZIA58814 SWA TC EAS2 Set Hemisphere Voltage Ratio 2021-06-25T19:24:35.678 OK 2021-06-25T19:24:35.803 OK 6 TC(202,143) ZIA58815 SWA TC EAS2 Set Hemisphere High Voltage 2021-06-25T19:24:37.678 OK 2021-06-25T19:24:37.803 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2021-06-25T19:24:39.678 OK 2021-06-25T19:24:48.052 OK 66 TC(202,173) ZIA58845 SWA TC EAS2 set preamp control data 2021-06-25T19:24:49.678 OK 2021-06-25T19:24:49.803 OK 4 TC(202,160) ZIA58832 SWA TC EAS2 Set New HV for MCP 2021-06-25T19:25:19.676 OK 2021-06-25T19:25:19.677 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2021-06-25T19:25:21.676 OK 2021-06-25T19:25:21.677 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2021-06-25T19:25:30.678 OK 2021-06-25T19:25:30.678 OK 14 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2021-06-25T19:25:40.676 OK 2021-06-25T19:25:41.426 OK 4 TC(200,141) ZIA58737 SWA TC initialize DPU SDP configuration 2021-06-25T19:26:00.677 OK 2021-06-25T19:26:00.803 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2021-06-25T19:26:10.683 OK 2021-06-25T19:26:10.808 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2021-06-25T22:01:02.694 OK 2021-06-25T22:01:02.943 ERR 20 TC(200,160) ZIA58726 SWA TC enter all sensor in Burst Mode Number of TC = 79 Number of TARS = 74 Number of TARF = 1 Number of TECS = 73 Number of TECF = 1 Number unacked = 4 Dupicate TARSF = 16 Dupicate TECSF = 15