============================================== TELECOMMANDS for 2021-09-03 ============================================== TC acceptation and status TC execution and status Size Service ID Label --------------------------- --------------------------- ---- ----------- -------- ----- 2021-09-03T01:05:00.680 OK 2021-09-03T01:05:00.680 OK 4 TC(200,165) ZIA58004 SWA TC enable/disable command to individual sensor 2021-09-03T01:05:02.682 OK 2021-09-03T01:05:02.682 OK 4 TC(200,176) ZIA58069 SWA TC reset the ERROR condition counters for the spec. Event 2021-09-03T01:05:04.682 OK 2021-09-03T01:05:04.682 OK 4 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2021-09-03T01:05:08.805 OK 2021-09-03T01:05:08.931 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2021-09-03T01:05:09.805 OK 2021-09-03T01:05:09.931 OK 6 TC(204,141) ZIA58913 SWA TC HIS run the specified macro 2021-09-03T01:05:12.682 OK 2021-09-03T01:05:12.682 OK 31 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-09-03T01:05:13.682 OK 2021-09-03T01:05:13.682 OK 6 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2021-09-03T01:05:43.682 OK 2021-09-03T01:05:43.682 OK 4 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-09-03T01:05:44.682 OK 2021-09-03T01:05:44.682 OK 4 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2021-09-03T01:05:45.682 OK 2021-09-03T01:05:45.806 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2021-09-03T01:05:55.682 OK 2021-09-03T01:05:55.806 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2021-09-03T01:06:05.682 OK 2021-09-03T01:06:05.806 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2021-09-03T01:06:15.682 OK 2021-09-03T01:06:15.806 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2021-09-03T01:06:25.682 OK 2021-09-03T01:06:25.806 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2021-09-03T01:06:35.682 OK 2021-09-03T01:06:35.806 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2021-09-03T01:06:45.682 OK 2021-09-03T01:06:45.806 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2021-09-03T01:06:55.682 OK 2021-09-03T01:06:55.806 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2021-09-03T01:07:05.682 OK 2021-09-03T01:07:05.806 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2021-09-03T01:07:15.682 OK 2021-09-03T01:07:15.806 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2021-09-03T01:07:25.682 OK 2021-09-03T01:07:25.682 OK 5 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2021-09-03T01:07:55.682 OK 2021-09-03T01:07:55.805 OK 6 TC(203,141) ZIA58863 SWA TC PAS write Master Control register 2021-09-03T01:07:57.682 OK 2021-09-03T01:07:57.805 OK 6 TC(203,141) ZIA58863 SWA TC PAS write Master Control register 2021-09-03T01:07:59.682 OK 2021-09-03T01:07:59.805 OK 4 TC(203,140) ZIA58862 SWA TC PAS write Pre-Amp power Control register 2021-09-03T01:08:04.682 OK 2021-09-03T01:08:05.180 OK 24 TC(203,154) ZIA58876 SWA TC PAS Upload Static Table 2021-09-03T01:08:09.682 OK 2021-09-03T01:08:13.180 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2021-09-03T01:08:39.682 OK 2021-09-03T01:08:39.805 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2021-09-03T01:08:44.682 OK 2021-09-03T01:23:58.432 OK 10 TC(203,134) ZIA58856 PAS HV Ramp UP 2021-09-03T01:27:12.684 OK 2021-09-03T01:27:12.684 OK 18 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2021-09-03T01:27:14.684 OK 2021-09-03T01:27:14.684 OK 4 TC(203,157) ZIA58943 SWA TC PAS start science 2021-09-03T01:28:54.684 OK 2021-09-03T01:28:54.684 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2021-09-03T01:29:14.684 OK 2021-09-03T01:29:17.182 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2021-09-03T02:28:08.815 OK 2021-09-03T02:28:08.940 OK 6 TC(204,141) ZIA58913 SWA TC HIS run the specified macro 2021-09-03T07:06:00.719 OK 2021-09-03T07:06:00.842 OK 4 TC(201,160) ZIA58784 SWA TC EAS1 Set New HV for MCP 2021-09-03T07:06:01.719 OK 2021-09-03T07:06:01.843 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2021-09-03T07:06:02.718 OK 2021-09-03T07:06:02.843 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2021-09-03T07:06:03.719 OK 2021-09-03T07:06:03.843 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2021-09-03T07:06:05.719 OK 2021-09-03T07:06:05.842 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2021-09-03T07:06:07.723 OK 2021-09-03T07:06:07.848 OK 4 TC(202,160) ZIA58832 SWA TC EAS2 Set New HV for MCP 2021-09-03T07:06:08.723 OK 2021-09-03T07:06:08.848 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-09-03T07:06:09.723 OK 2021-09-03T07:06:09.848 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-09-03T07:06:10.723 OK 2021-09-03T07:06:10.848 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-09-03T07:06:12.723 OK 2021-09-03T07:06:12.848 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2021-09-03T07:10:30.724 OK 2021-09-03T07:10:30.850 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2021-09-03T07:10:32.723 OK 2021-09-03T07:10:32.849 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2021-09-03T07:10:34.720 OK 2021-09-03T07:10:34.721 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-09-03T07:10:35.724 OK 2021-09-03T07:10:35.724 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-09-03T07:10:36.717 OK 2021-09-03T07:10:36.717 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2021-09-03T07:10:37.717 OK 2021-09-03T07:10:37.717 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2021-09-03T07:10:38.717 OK 2021-09-03T07:10:38.717 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2021-09-03T07:10:39.719 OK 2021-09-03T07:15:50.468 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2021-09-03T07:10:40.720 OK 2021-09-03T07:16:19.343 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2021-09-03T07:17:40.720 OK 2021-09-03T07:22:51.344 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2021-09-03T07:17:41.720 OK 2021-09-03T07:23:20.219 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2021-09-03T07:24:41.721 OK 2021-09-03T07:30:20.219 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2021-09-03T07:24:42.721 OK 2021-09-03T07:29:53.345 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2021-09-03T07:31:42.721 OK 2021-09-03T07:37:21.220 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2021-09-03T07:31:43.722 OK 2021-09-03T07:36:54.346 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2021-09-03T07:38:43.719 OK 2021-09-03T07:38:43.720 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2021-09-03T07:38:44.719 OK 2021-09-03T07:38:44.720 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2021-09-03T07:38:45.719 OK 2021-09-03T07:38:45.720 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2021-09-03T07:39:36.722 OK 2021-09-03T07:39:36.846 OK 6 TC(201,142) ZIA58766 SWA TC EAS1 Set Hemisphere Voltage Ratio 2021-09-03T07:39:38.722 OK 2021-09-03T07:39:38.846 OK 6 TC(201,143) ZIA58767 SWA TC EAS1 Set Hemisphere High Voltage 2021-09-03T07:39:40.722 OK 2021-09-03T07:39:40.846 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2021-09-03T07:39:42.722 OK 2021-09-03T07:39:42.846 OK 6 TC(202,142) ZIA58814 SWA TC EAS2 Set Hemisphere Voltage Ratio 2021-09-03T07:39:44.723 OK 2021-09-03T07:39:44.846 OK 6 TC(202,143) ZIA58815 SWA TC EAS2 Set Hemisphere High Voltage 2021-09-03T07:39:46.722 OK 2021-09-03T07:39:46.846 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2021-09-03T07:39:48.724 OK 2021-09-03T07:39:48.724 OK 14 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2021-09-03T07:39:50.722 OK 2021-09-03T07:39:50.846 OK 4 TC(202,160) ZIA58832 SWA TC EAS2 Set New HV for MCP 2021-09-03T07:39:51.723 OK 2021-09-03T07:39:51.846 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-09-03T07:39:52.723 OK 2021-09-03T07:39:52.846 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-09-03T07:39:53.723 OK 2021-09-03T07:39:53.846 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-09-03T07:39:55.723 OK 2021-09-03T07:39:55.846 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2021-09-03T07:39:57.723 OK 2021-09-03T07:43:42.846 OK 16 TC(201,166) ZIA58790 SWA TC EAS1 enter in engineering 4 mode 2021-09-03T07:44:57.723 OK 2021-09-03T07:48:42.846 OK 16 TC(201,166) ZIA58790 SWA TC EAS1 enter in engineering 4 mode 2021-09-03T07:49:57.724 OK 2021-09-03T07:53:42.847 OK 16 TC(201,166) ZIA58790 SWA TC EAS1 enter in engineering 4 mode 2021-09-03T07:54:57.725 OK 2021-09-03T07:58:42.847 OK 16 TC(201,166) ZIA58790 SWA TC EAS1 enter in engineering 4 mode 2021-09-03T07:59:57.725 OK 2021-09-03T08:02:41.223 OK 16 TC(201,166) ZIA58790 SWA TC EAS1 enter in engineering 4 mode 2021-09-03T08:04:57.726 OK 2021-09-03T08:04:57.848 OK 6 TC(201,142) ZIA58766 SWA TC EAS1 Set Hemisphere Voltage Ratio 2021-09-03T08:04:59.725 OK 2021-09-03T08:04:59.848 OK 6 TC(201,143) ZIA58767 SWA TC EAS1 Set Hemisphere High Voltage 2021-09-03T08:05:01.725 OK 2021-09-03T08:05:01.848 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2021-09-03T08:05:03.725 OK 2021-09-03T08:05:12.098 OK 66 TC(201,173) ZIA58797 SWA TC EAS1 set preamp control data 2021-09-03T08:05:14.735 OK 2021-09-03T08:05:14.735 OK 14 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2021-09-03T08:05:16.726 OK 2021-09-03T08:05:16.848 OK 4 TC(201,160) ZIA58784 SWA TC EAS1 Set New HV for MCP 2021-09-03T08:05:17.726 OK 2021-09-03T08:05:17.849 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2021-09-03T08:05:18.725 OK 2021-09-03T08:05:18.849 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2021-09-03T08:05:19.725 OK 2021-09-03T08:05:19.849 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2021-09-03T08:05:21.725 OK 2021-09-03T08:05:21.848 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2021-09-03T08:05:23.733 OK 2021-09-03T08:05:23.875 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2021-09-03T08:05:25.732 OK 2021-09-03T08:05:25.732 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-09-03T08:05:26.729 OK 2021-09-03T08:09:11.979 OK 16 TC(202,166) ZIA58838 SWA TC EAS2 enter in engineering 4 mode 2021-09-03T08:10:26.730 OK 2021-09-03T08:14:11.854 OK 16 TC(202,166) ZIA58838 SWA TC EAS2 enter in engineering 4 mode 2021-09-03T08:15:26.730 OK 2021-09-03T08:19:11.855 OK 16 TC(202,166) ZIA58838 SWA TC EAS2 enter in engineering 4 mode 2021-09-03T08:20:26.730 OK 2021-09-03T08:24:11.855 OK 16 TC(202,166) ZIA58838 SWA TC EAS2 enter in engineering 4 mode 2021-09-03T08:25:26.731 OK 2021-09-03T08:28:10.229 OK 16 TC(202,166) ZIA58838 SWA TC EAS2 enter in engineering 4 mode 2021-09-03T08:27:30.726 OK 2021-09-03T08:27:33.100 OK 20 TC(200,160) ZIA58726 SWA TC enter all sensor in Burst Mode 2021-09-03T08:30:26.732 OK 2021-09-03T08:30:26.860 OK 6 TC(202,142) ZIA58814 SWA TC EAS2 Set Hemisphere Voltage Ratio 2021-09-03T08:30:28.731 OK 2021-09-03T08:30:28.861 OK 6 TC(202,143) ZIA58815 SWA TC EAS2 Set Hemisphere High Voltage 2021-09-03T08:30:30.732 OK 2021-09-03T08:30:30.856 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2021-09-03T08:30:32.732 OK 2021-09-03T08:30:41.105 OK 66 TC(202,173) ZIA58845 SWA TC EAS2 set preamp control data 2021-09-03T08:30:43.733 OK 2021-09-03T08:30:43.733 OK 14 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2021-09-03T08:30:45.731 OK 2021-09-03T08:30:45.859 OK 4 TC(202,160) ZIA58832 SWA TC EAS2 Set New HV for MCP 2021-09-03T08:30:46.732 OK 2021-09-03T08:30:46.860 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-09-03T08:30:47.732 OK 2021-09-03T08:30:47.861 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-09-03T08:30:48.732 OK 2021-09-03T08:30:48.861 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-09-03T08:30:50.732 OK 2021-09-03T08:30:50.856 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2021-09-03T08:45:00.729 OK 2021-09-03T08:45:00.729 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2021-09-03T11:00:00.744 OK 2021-09-03T11:00:00.744 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2021-09-03T11:33:37.886 OK 2021-09-03T11:33:38.010 OK 6 TC(204,141) ZIA58913 SWA TC HIS run the specified macro 2021-09-03T11:33:46.758 OK 2021-09-03T11:33:46.758 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2021-09-03T11:33:54.756 OK 2021-09-03T11:33:54.882 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2021-09-03T11:33:56.751 OK 2021-09-03T11:33:56.877 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2021-09-03T11:33:58.751 OK 2021-09-03T11:33:58.881 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2021-09-03T11:34:00.746 OK 2021-09-03T11:34:00.870 OK 4 TC(201,160) ZIA58784 SWA TC EAS1 Set New HV for MCP 2021-09-03T11:34:01.746 OK 2021-09-03T11:34:01.870 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2021-09-03T11:34:02.746 OK 2021-09-03T11:34:02.870 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2021-09-03T11:34:03.746 OK 2021-09-03T11:34:03.870 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2021-09-03T11:34:05.747 OK 2021-09-03T11:34:05.870 OK 4 TC(202,160) ZIA58832 SWA TC EAS2 Set New HV for MCP 2021-09-03T11:34:06.747 OK 2021-09-03T11:34:06.871 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-09-03T11:34:07.747 OK 2021-09-03T11:34:07.871 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-09-03T11:34:08.747 OK 2021-09-03T11:34:08.871 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-09-03T11:34:10.747 OK 2021-09-03T11:34:10.747 OK 4 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-09-03T11:34:12.745 OK 2021-09-03T11:34:12.745 OK 4 TC(200,165) ZIA58004 SWA TC enable/disable command to individual sensor 2021-09-03T11:49:37.747 OK 2021-09-03T11:49:37.747 OK 4 TC(200,165) ZIA58004 SWA TC enable/disable command to individual sensor 2021-09-03T11:49:39.749 OK 2021-09-03T11:49:39.749 OK 4 TC(200,176) ZIA58069 SWA TC reset the ERROR condition counters for the spec. Event 2021-09-03T11:49:41.749 OK 2021-09-03T11:49:41.749 OK 4 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2021-09-03T11:49:43.748 OK 2021-09-03T11:49:43.749 OK 4 TC(203,157) ZIA58943 SWA TC PAS start science 2021-09-03T11:49:45.872 OK 2021-09-03T11:49:45.872 OK 6 TC(204,141) ZIA58913 SWA TC HIS run the specified macro 2021-09-03T11:51:23.749 OK 2021-09-03T11:51:23.749 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2021-09-03T11:51:43.749 OK 2021-09-03T11:51:45.247 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2021-09-03T12:00:00.750 OK 2021-09-03T12:00:00.750 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2021-09-03T12:00:10.750 OK 2021-09-03T12:07:24.128 OK 22 TC(203,128) ZIA58850 SWA TC PAS enter in Calibration mode 2021-09-03T12:08:30.750 OK 2021-09-03T12:08:30.751 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2021-09-03T12:08:38.750 OK 2021-09-03T12:08:41.248 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2021-09-03T12:09:45.750 OK 2021-09-03T12:09:45.874 OK 4 TC(201,160) ZIA58784 SWA TC EAS1 Set New HV for MCP 2021-09-03T12:09:46.750 OK 2021-09-03T12:09:46.874 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2021-09-03T12:09:47.750 OK 2021-09-03T12:09:47.874 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2021-09-03T12:09:48.750 OK 2021-09-03T12:09:48.874 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2021-09-03T12:09:50.750 OK 2021-09-03T12:09:50.874 OK 4 TC(202,160) ZIA58832 SWA TC EAS2 Set New HV for MCP 2021-09-03T12:09:51.751 OK 2021-09-03T12:09:51.874 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-09-03T12:09:52.750 OK 2021-09-03T12:09:52.874 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-09-03T12:09:53.750 OK 2021-09-03T12:09:53.874 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-09-03T12:09:55.750 OK 2021-09-03T12:09:55.874 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2021-09-03T12:09:57.754 OK 2021-09-03T12:09:57.879 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2021-09-03T12:15:00.751 OK 2021-09-03T12:15:00.751 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2021-09-03T19:00:00.665 OK 2021-09-03T19:00:00.665 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2021-09-03T19:27:30.668 OK 2021-09-03T19:27:33.169 OK 20 TC(200,160) ZIA58726 SWA TC enter all sensor in Burst Mode 2021-09-03T19:45:00.670 OK 2021-09-03T19:45:00.670 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling Number of TC = 147 Number of TARS = 147 Number of TARF = 0 Number of TECS = 147 Number of TECF = 0 Number unacked = 0 Dupicate TARSF = 77 Dupicate TECSF = 77