============================================== TELECOMMANDS for 2021-11-11 ============================================== TC acceptation and status TC execution and status Size Service ID Label --------------------------- --------------------------- ---- ----------- -------- ----- 2021-11-11T05:00:00.610 OK 2021-11-11T05:00:00.611 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2021-11-11T05:27:30.613 OK 2021-11-11T05:27:31.239 OK 20 TC(200,160) ZIA58726 SWA TC enter all sensor in Burst Mode 2021-11-11T05:45:00.615 OK 2021-11-11T05:45:00.615 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2021-11-11T10:45:00.646 OK 2021-11-11T10:45:00.646 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2021-11-11T11:15:00.653 OK 2021-11-11T11:15:00.794 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2021-11-11T11:15:02.654 OK 2021-11-11T11:15:02.794 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2021-11-11T11:15:04.651 OK 2021-11-11T11:15:04.651 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-11-11T11:15:05.668 OK 2021-11-11T11:15:05.668 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-11-11T11:15:06.649 OK 2021-11-11T11:15:06.649 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2021-11-11T11:15:07.649 OK 2021-11-11T11:15:07.649 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2021-11-11T11:15:08.649 OK 2021-11-11T11:15:08.649 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2021-11-11T11:15:09.650 OK 2021-11-11T11:20:20.525 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2021-11-11T11:15:10.650 OK 2021-11-11T11:20:49.400 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2021-11-11T11:22:10.650 OK 2021-11-11T11:27:49.276 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2021-11-11T11:22:11.651 OK 2021-11-11T11:27:22.401 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2021-11-11T11:29:11.651 OK 2021-11-11T11:34:22.401 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2021-11-11T11:29:12.651 OK 2021-11-11T11:34:51.277 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2021-11-11T11:36:12.652 OK 2021-11-11T11:41:51.277 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2021-11-11T11:36:13.652 OK 2021-11-11T11:41:24.403 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2021-11-11T11:43:13.652 OK 2021-11-11T11:43:13.652 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2021-11-11T11:43:14.652 OK 2021-11-11T11:43:14.652 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2021-11-11T11:43:15.652 OK 2021-11-11T11:43:15.652 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2021-11-11T11:44:06.653 OK 2021-11-11T11:44:06.778 OK 6 TC(201,142) ZIA58766 SWA TC EAS1 Set Hemisphere Voltage Ratio 2021-11-11T11:44:08.653 OK 2021-11-11T11:44:08.778 OK 6 TC(201,143) ZIA58767 SWA TC EAS1 Set Hemisphere High Voltage 2021-11-11T11:44:10.653 OK 2021-11-11T11:44:10.778 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2021-11-11T11:44:12.653 OK 2021-11-11T11:44:12.778 OK 6 TC(202,142) ZIA58814 SWA TC EAS2 Set Hemisphere Voltage Ratio 2021-11-11T11:44:14.653 OK 2021-11-11T11:44:14.778 OK 6 TC(202,143) ZIA58815 SWA TC EAS2 Set Hemisphere High Voltage 2021-11-11T11:44:16.653 OK 2021-11-11T11:44:16.778 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2021-11-11T11:44:18.656 OK 2021-11-11T11:44:18.656 OK 14 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2021-11-11T11:44:20.653 OK 2021-11-11T11:44:20.654 OK 14 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2021-11-11T11:44:22.653 OK 2021-11-11T11:44:22.778 OK 4 TC(201,160) ZIA58784 SWA TC EAS1 Set New HV for MCP 2021-11-11T11:44:23.653 OK 2021-11-11T11:44:23.778 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2021-11-11T11:44:24.653 OK 2021-11-11T11:44:24.778 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2021-11-11T11:44:25.653 OK 2021-11-11T11:44:25.778 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2021-11-11T11:44:27.653 OK 2021-11-11T11:44:27.778 OK 4 TC(202,160) ZIA58832 SWA TC EAS2 Set New HV for MCP 2021-11-11T11:44:28.653 OK 2021-11-11T11:44:28.778 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-11-11T11:44:29.653 OK 2021-11-11T11:44:29.778 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-11-11T11:44:30.653 OK 2021-11-11T11:44:30.778 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-11-11T11:44:32.653 OK 2021-11-11T11:44:32.778 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2021-11-11T11:44:34.656 OK 2021-11-11T11:44:34.798 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2021-11-11T12:00:00.664 OK 2021-11-11T12:00:00.665 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2021-11-11T12:00:10.664 OK 2021-11-11T12:07:26.295 OK 22 TC(203,128) ZIA58850 SWA TC PAS enter in Calibration mode 2021-11-11T12:08:30.665 OK 2021-11-11T12:08:30.666 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2021-11-11T12:08:38.667 OK 2021-11-11T12:08:39.416 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2021-11-11T12:10:00.654 OK 2021-11-11T12:10:00.654 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2021-11-11T17:00:00.684 OK 2021-11-11T17:00:00.684 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2021-11-11T17:27:30.687 OK 2021-11-11T17:27:31.313 OK 20 TC(200,160) ZIA58726 SWA TC enter all sensor in Burst Mode 2021-11-11T17:45:00.688 OK 2021-11-11T17:45:00.689 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling Number of TC = 48 Number of TARS = 48 Number of TARF = 0 Number of TECS = 48 Number of TECF = 0 Number unacked = 0 Dupicate TARSF = 3 Dupicate TECSF = 3