============================================== TELECOMMANDS for 2021-11-20 ============================================== TC acceptation and status TC execution and status Size Service ID Label --------------------------- --------------------------- ---- ----------- -------- ----- 2021-11-20T05:00:00.680 OK 2021-11-20T05:00:00.680 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2021-11-20T05:27:30.683 OK 2021-11-20T05:27:32.559 OK 20 TC(200,160) ZIA58726 SWA TC enter all sensor in Burst Mode 2021-11-20T05:45:00.685 OK 2021-11-20T05:45:00.685 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2021-11-20T11:30:00.595 OK 2021-11-20T11:30:00.595 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2021-11-20T12:00:00.611 OK 2021-11-20T12:00:00.612 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2021-11-20T12:00:10.611 OK 2021-11-20T12:07:23.613 OK 22 TC(203,128) ZIA58850 SWA TC PAS enter in Calibration mode 2021-11-20T12:08:30.612 OK 2021-11-20T12:08:30.613 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2021-11-20T12:08:38.611 OK 2021-11-20T12:08:40.735 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2021-11-20T13:13:55.610 OK 2021-11-20T13:13:55.736 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2021-11-20T13:13:57.614 OK 2021-11-20T13:13:57.614 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-11-20T13:14:00.606 OK 2021-11-20T13:17:45.982 OK 16 TC(201,166) ZIA58790 SWA TC EAS1 enter in engineering 4 mode 2021-11-20T13:19:00.607 OK 2021-11-20T13:22:45.857 OK 16 TC(201,166) ZIA58790 SWA TC EAS1 enter in engineering 4 mode 2021-11-20T13:24:00.607 OK 2021-11-20T13:27:45.858 OK 16 TC(201,166) ZIA58790 SWA TC EAS1 enter in engineering 4 mode 2021-11-20T13:29:00.608 OK 2021-11-20T13:32:45.858 OK 16 TC(201,166) ZIA58790 SWA TC EAS1 enter in engineering 4 mode 2021-11-20T13:34:00.608 OK 2021-11-20T13:36:44.358 OK 16 TC(201,166) ZIA58790 SWA TC EAS1 enter in engineering 4 mode 2021-11-20T13:39:00.609 OK 2021-11-20T13:39:00.734 OK 6 TC(201,142) ZIA58766 SWA TC EAS1 Set Hemisphere Voltage Ratio 2021-11-20T13:39:02.609 OK 2021-11-20T13:39:02.734 OK 6 TC(201,143) ZIA58767 SWA TC EAS1 Set Hemisphere High Voltage 2021-11-20T13:39:04.609 OK 2021-11-20T13:39:04.734 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2021-11-20T13:39:06.609 OK 2021-11-20T13:39:14.984 OK 66 TC(201,173) ZIA58797 SWA TC EAS1 set preamp control data 2021-11-20T13:39:17.615 OK 2021-11-20T13:39:17.615 OK 14 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2021-11-20T13:39:19.609 OK 2021-11-20T13:39:19.734 OK 4 TC(201,160) ZIA58784 SWA TC EAS1 Set New HV for MCP 2021-11-20T13:39:20.609 OK 2021-11-20T13:39:20.734 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2021-11-20T13:39:21.609 OK 2021-11-20T13:39:21.734 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2021-11-20T13:39:22.609 OK 2021-11-20T13:39:22.734 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2021-11-20T13:39:24.609 OK 2021-11-20T13:39:24.734 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2021-11-20T13:39:26.618 OK 2021-11-20T13:39:26.743 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2021-11-20T13:39:28.614 OK 2021-11-20T13:39:28.614 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-11-20T13:39:29.613 OK 2021-11-20T13:43:14.988 OK 16 TC(202,166) ZIA58838 SWA TC EAS2 enter in engineering 4 mode 2021-11-20T13:44:29.618 OK 2021-11-20T13:48:14.864 OK 16 TC(202,166) ZIA58838 SWA TC EAS2 enter in engineering 4 mode 2021-11-20T13:49:29.618 OK 2021-11-20T13:53:14.864 OK 16 TC(202,166) ZIA58838 SWA TC EAS2 enter in engineering 4 mode 2021-11-20T13:54:29.618 OK 2021-11-20T13:58:14.865 OK 16 TC(202,166) ZIA58838 SWA TC EAS2 enter in engineering 4 mode 2021-11-20T13:59:29.619 OK 2021-11-20T14:02:13.366 OK 16 TC(202,166) ZIA58838 SWA TC EAS2 enter in engineering 4 mode 2021-11-20T14:04:29.620 OK 2021-11-20T14:04:29.741 OK 6 TC(202,142) ZIA58814 SWA TC EAS2 Set Hemisphere Voltage Ratio 2021-11-20T14:04:31.618 OK 2021-11-20T14:04:31.741 OK 6 TC(202,143) ZIA58815 SWA TC EAS2 Set Hemisphere High Voltage 2021-11-20T14:04:33.616 OK 2021-11-20T14:04:33.741 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2021-11-20T14:04:35.617 OK 2021-11-20T14:04:43.990 OK 66 TC(202,173) ZIA58845 SWA TC EAS2 set preamp control data 2021-11-20T14:04:46.617 OK 2021-11-20T14:04:46.617 OK 14 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2021-11-20T14:04:48.619 OK 2021-11-20T14:04:48.741 OK 4 TC(202,160) ZIA58832 SWA TC EAS2 Set New HV for MCP 2021-11-20T14:04:49.620 OK 2021-11-20T14:04:49.741 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-11-20T14:04:50.619 OK 2021-11-20T14:04:50.741 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-11-20T14:04:51.620 OK 2021-11-20T14:04:51.741 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2021-11-20T14:04:53.616 OK 2021-11-20T14:04:53.741 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2021-11-20T14:04:55.748 OK 2021-11-20T14:04:55.873 OK 2 TC(204,181) ZIA58941 SWA TC HIS safe nominal 2021-11-20T14:22:36.617 OK 2021-11-20T14:22:36.743 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2021-11-20T14:22:38.621 OK 2021-11-20T14:22:38.743 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2021-11-20T14:22:40.619 OK 2021-11-20T14:22:40.619 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-11-20T14:22:41.617 OK 2021-11-20T14:22:41.617 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-11-20T14:22:42.612 OK 2021-11-20T14:22:42.613 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2021-11-20T14:22:43.612 OK 2021-11-20T14:22:43.613 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2021-11-20T14:22:44.612 OK 2021-11-20T14:22:44.613 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2021-11-20T14:22:45.613 OK 2021-11-20T14:27:55.614 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2021-11-20T14:22:46.614 OK 2021-11-20T14:28:25.241 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2021-11-20T14:29:46.614 OK 2021-11-20T14:35:25.115 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2021-11-20T14:29:47.615 OK 2021-11-20T14:34:57.490 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2021-11-20T14:36:47.615 OK 2021-11-20T14:41:57.491 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2021-11-20T14:36:48.615 OK 2021-11-20T14:42:27.115 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2021-11-20T14:43:48.615 OK 2021-11-20T14:49:27.116 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2021-11-20T14:43:49.616 OK 2021-11-20T14:48:59.492 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2021-11-20T14:50:49.615 OK 2021-11-20T14:50:49.615 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2021-11-20T14:50:50.615 OK 2021-11-20T14:50:50.615 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2021-11-20T14:50:51.615 OK 2021-11-20T14:50:51.615 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2021-11-20T14:51:42.616 OK 2021-11-20T14:51:42.742 OK 6 TC(201,142) ZIA58766 SWA TC EAS1 Set Hemisphere Voltage Ratio 2021-11-20T14:51:44.616 OK 2021-11-20T14:51:44.742 OK 6 TC(201,143) ZIA58767 SWA TC EAS1 Set Hemisphere High Voltage 2021-11-20T14:51:46.616 OK 2021-11-20T14:51:46.742 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2021-11-20T14:51:48.617 OK 2021-11-20T14:51:48.742 OK 6 TC(202,142) ZIA58814 SWA TC EAS2 Set Hemisphere Voltage Ratio 2021-11-20T14:51:50.617 OK 2021-11-20T14:51:50.742 OK 6 TC(202,143) ZIA58815 SWA TC EAS2 Set Hemisphere High Voltage 2021-11-20T14:51:52.617 OK 2021-11-20T14:51:52.742 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2021-11-20T14:51:54.617 OK 2021-11-20T14:51:54.617 OK 14 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2021-11-20T14:51:56.618 OK 2021-11-20T14:51:56.618 OK 14 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2021-11-20T14:51:58.616 OK 2021-11-20T14:51:58.742 OK 4 TC(201,160) ZIA58784 SWA TC EAS1 Set New HV for MCP 2021-11-20T14:52:30.617 OK 2021-11-20T14:52:30.742 OK 4 TC(202,160) ZIA58832 SWA TC EAS2 Set New HV for MCP 2021-11-20T14:53:02.617 OK 2021-11-20T14:53:02.617 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2021-11-20T14:53:10.617 OK 2021-11-20T14:53:10.617 OK 31 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-11-20T14:53:11.617 OK 2021-11-20T14:53:11.741 OK 4 TC(203,140) ZIA58862 SWA TC PAS write Pre-Amp power Control register 2021-11-20T14:53:16.617 OK 2021-11-20T14:54:50.244 OK 10 TC(203,135) ZIA58857 PAS HV Ramp DOWN 2021-11-20T14:56:16.617 OK 2021-11-20T14:56:16.742 OK 6 TC(203,141) ZIA58863 SWA TC PAS write Master Control register 2021-11-20T14:56:17.617 OK 2021-11-20T14:56:17.743 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2021-11-20T14:56:32.617 OK 2021-11-20T14:56:32.743 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2021-11-20T14:56:47.617 OK 2021-11-20T14:56:47.743 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2021-11-20T14:57:02.617 OK 2021-11-20T14:57:02.743 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2021-11-20T14:57:17.617 OK 2021-11-20T14:57:17.743 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2021-11-20T14:57:32.617 OK 2021-11-20T14:57:32.743 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2021-11-20T14:57:55.742 OK 2021-11-20T14:57:55.867 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2021-11-20T14:58:56.618 OK 2021-11-20T14:58:56.618 OK 4 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-11-20T14:58:58.616 OK 2021-11-20T14:58:58.616 OK 4 TC(200,165) ZIA58004 SWA TC enable/disable command to individual sensor 2021-11-20T15:06:00.617 OK 2021-11-20T15:06:00.617 OK 4 TC(200,165) ZIA58004 SWA TC enable/disable command to individual sensor 2021-11-20T15:07:00.619 OK 2021-11-20T15:07:00.619 OK 4 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-11-20T15:07:01.618 OK 2021-11-20T15:07:02.244 OK 2 TC(200,154) ZIA58730 SWA TC DPU switch OFF HIS 2021-11-20T15:08:00.618 OK 2021-11-20T15:08:00.618 OK 31 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-11-20T15:08:01.618 OK 2021-11-20T15:08:01.743 OK 4 TC(203,140) ZIA58862 SWA TC PAS write Pre-Amp power Control register 2021-11-20T15:08:06.618 ERR -- 10 TC(203,135) ZIA58857 PAS HV Ramp DOWN 2021-11-20T15:11:06.618 OK 2021-11-20T15:11:06.743 OK 6 TC(203,141) ZIA58863 SWA TC PAS write Master Control register 2021-11-20T15:11:07.618 OK 2021-11-20T15:13:38.994 OK 2 TC(203,137) ZIA58859 PAS Normal Power OFF 2021-11-20T15:12:07.619 OK 2021-11-20T15:12:07.619 OK 4 TC( 3, 6) ZIA58051 SWA TC disable HK report generation 2021-11-20T15:13:00.619 OK 2021-11-20T15:13:00.619 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-11-20T15:13:02.618 OK 2021-11-20T15:13:02.743 OK 6 TC(201,133) ZIA58757 SWA TC EAS1 Sensor Reset 2021-11-20T15:13:07.618 OK 2021-11-20T15:13:51.993 OK 2 TC(201,137) ZIA58761 SWA TC EAS1 normal power off 2021-11-20T15:13:52.618 OK 2021-11-20T15:13:52.619 OK 4 TC( 3, 6) ZIA58051 SWA TC disable HK report generation 2021-11-20T15:14:00.618 OK 2021-11-20T15:14:00.619 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2021-11-20T15:14:02.618 OK 2021-11-20T15:14:02.743 OK 6 TC(202,133) ZIA58805 SWA TC EAS2 Sensor Reset 2021-11-20T15:14:07.618 OK 2021-11-20T15:14:51.993 OK 2 TC(202,137) ZIA58809 SWA TC EAS2 normal power off 2021-11-20T15:14:52.618 OK 2021-11-20T15:14:52.618 OK 4 TC( 3, 6) ZIA58051 SWA TC disable HK report generation 2021-11-20T15:17:35.618 OK 2021-11-20T15:17:35.618 OK 4 TC(200,165) ZIA58004 SWA TC enable/disable command to individual sensor Number of TC = 103 Number of TARS = 102 Number of TARF = 1 Number of TECS = 102 Number of TECF = 0 Number unacked = 0 Dupicate TARSF = 100 Dupicate TECSF = 99