============================================== TELECOMMANDS for 2022-10-21 ============================================== TC acceptation and status TC execution and status Size Service ID Label --------------------------- --------------------------- ---- ----------- -------- ----- 2022-10-21T00:00:00.721 OK 2022-10-21T00:00:00.829 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2022-10-21T00:00:01.703 OK 2022-10-21T00:00:01.704 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2022-10-21T00:00:10.710 OK 2022-10-21T00:00:10.710 OK 4 TC(203,157) ZIA58943 SWA TC PAS start science 2022-10-21T00:01:50.712 OK 2022-10-21T00:01:50.713 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2022-10-21T00:02:10.710 OK 2022-10-21T00:02:14.576 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2022-10-21T05:21:30.726 OK 2022-10-21T05:21:30.726 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2022-10-21T05:27:30.727 OK 2022-10-21T05:27:34.481 OK 20 TC(200,160) ZIA58726 SWA TC enter all sensor in Burst Mode 2022-10-21T05:37:30.728 OK 2022-10-21T05:37:30.728 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2022-10-21T06:00:00.778 OK 2022-10-21T06:00:00.868 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2022-10-21T06:00:01.741 OK 2022-10-21T06:00:01.742 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2022-10-21T06:00:10.743 OK 2022-10-21T06:00:10.743 OK 4 TC(203,157) ZIA58943 SWA TC PAS start science 2022-10-21T06:01:50.743 OK 2022-10-21T06:01:50.744 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2022-10-21T06:02:10.743 OK 2022-10-21T06:02:14.615 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2022-10-21T11:54:00.644 OK 2022-10-21T11:54:00.644 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2022-10-21T11:59:20.657 OK 2022-10-21T11:59:20.658 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2022-10-21T11:59:30.657 OK 2022-10-21T12:08:21.538 OK 22 TC(203,128) ZIA58850 SWA TC PAS enter in Calibration mode 2022-10-21T12:09:40.658 OK 2022-10-21T12:09:40.659 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2022-10-21T12:09:58.658 OK 2022-10-21T12:10:02.654 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2022-10-21T12:10:00.645 OK 2022-10-21T12:10:00.646 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2022-10-21T17:21:30.679 OK 2022-10-21T17:21:30.679 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2022-10-21T17:27:30.680 OK 2022-10-21T17:27:34.556 OK 20 TC(200,160) ZIA58726 SWA TC enter all sensor in Burst Mode 2022-10-21T17:42:30.681 OK 2022-10-21T17:42:30.681 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2022-10-21T18:00:00.696 OK 2022-10-21T18:00:00.845 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2022-10-21T18:00:01.701 OK 2022-10-21T18:00:01.701 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2022-10-21T18:00:10.696 OK 2022-10-21T18:00:10.696 OK 4 TC(203,157) ZIA58943 SWA TC PAS start science 2022-10-21T18:01:50.696 OK 2022-10-21T18:01:50.697 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2022-10-21T18:02:10.697 OK 2022-10-21T18:02:14.692 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2022-10-21T23:05:51.853 OK 2022-10-21T23:05:51.978 OK 2 TC(204,181) ZIA58941 SWA TC HIS safe nominal 2022-10-21T23:52:52.721 OK 2022-10-21T23:52:52.721 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2022-10-21T23:53:06.731 OK 2022-10-21T23:53:06.732 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2022-10-21T23:53:14.731 OK 2022-10-21T23:53:14.731 OK 31 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2022-10-21T23:53:15.731 OK 2022-10-21T23:53:15.856 OK 4 TC(203,140) ZIA58862 SWA TC PAS write Pre-Amp power Control register 2022-10-21T23:53:20.755 OK 2022-10-21T23:54:54.482 OK 10 TC(203,135) ZIA58857 PAS HV Ramp DOWN 2022-10-21T23:56:20.735 OK 2022-10-21T23:56:20.865 OK 6 TC(203,141) ZIA58863 SWA TC PAS write Master Control register 2022-10-21T23:56:21.734 OK 2022-10-21T23:56:21.859 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2022-10-21T23:56:36.732 OK 2022-10-21T23:56:36.857 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2022-10-21T23:56:51.734 OK 2022-10-21T23:56:51.859 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2022-10-21T23:57:06.732 OK 2022-10-21T23:57:06.858 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2022-10-21T23:57:21.734 OK 2022-10-21T23:57:21.859 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2022-10-21T23:57:36.732 OK 2022-10-21T23:57:36.858 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2022-10-21T23:57:51.858 OK 2022-10-21T23:57:51.859 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2022-10-21T23:58:52.727 OK 2022-10-21T23:58:52.853 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2022-10-21T23:58:54.727 OK 2022-10-21T23:58:54.853 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2022-10-21T23:58:56.723 OK 2022-10-21T23:58:56.849 OK 4 TC(201,160) ZIA58784 SWA TC EAS1 Set New HV for MCP 2022-10-21T23:59:26.723 OK 2022-10-21T23:59:26.849 OK 4 TC(202,160) ZIA58832 SWA TC EAS2 Set New HV for MCP 2022-10-21T23:59:56.724 OK 2022-10-21T23:59:56.724 OK 4 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2022-10-21T23:59:58.722 OK 2022-10-21T23:59:58.722 OK 4 TC(200,165) ZIA58004 SWA TC enable/disable command to individual sensor Number of TC = 47 Number of TARS = 47 Number of TARF = 0 Number of TECS = 47 Number of TECF = 0 Number unacked = 0 Unknown TARF = 0 Unknown TECF = 0 Dupicate TARSF = 8 Dupicate TECSF = 8