============================================== TELECOMMANDS for 2023-02-17 ============================================== TC acceptation and status TC execution and status Size Service ID Label --------------------------- --------------------------- ---- ----------- -------- ----- 2023-02-17T00:00:00.723 OK 2023-02-17T00:00:00.878 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2023-02-17T00:00:01.722 OK 2023-02-17T00:00:01.723 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2023-02-17T00:00:10.723 OK 2023-02-17T00:00:10.723 OK 4 TC(203,157) ZIA58943 SWA TC PAS start science 2023-02-17T00:01:50.723 OK 2023-02-17T00:01:50.723 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2023-02-17T00:02:10.723 OK 2023-02-17T00:02:12.473 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2023-02-17T05:21:30.747 OK 2023-02-17T05:21:30.747 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2023-02-17T05:27:30.748 OK 2023-02-17T05:27:32.374 OK 20 TC(200,160) ZIA58726 SWA TC enter all sensor in Burst Mode 2023-02-17T05:37:30.624 OK 2023-02-17T05:37:30.624 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2023-02-17T06:00:00.635 OK 2023-02-17T06:00:00.760 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2023-02-17T06:00:01.635 OK 2023-02-17T06:00:01.636 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2023-02-17T06:00:10.635 OK 2023-02-17T06:00:10.636 OK 4 TC(203,157) ZIA58943 SWA TC PAS start science 2023-02-17T06:01:50.654 OK 2023-02-17T06:01:50.655 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2023-02-17T06:02:10.659 OK 2023-02-17T06:02:12.510 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2023-02-17T11:53:36.663 OK 2023-02-17T11:53:36.664 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2023-02-17T11:59:36.677 OK 2023-02-17T11:59:36.678 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2023-02-17T11:59:46.677 OK 2023-02-17T12:08:35.432 OK 22 TC(203,128) ZIA58850 SWA TC PAS enter in Calibration mode 2023-02-17T12:10:00.674 OK 2023-02-17T12:10:00.675 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2023-02-17T12:10:20.674 OK 2023-02-17T12:10:24.550 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2023-02-17T12:10:30.665 OK 2023-02-17T12:10:30.665 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2023-02-17T16:09:00.690 OK 2023-02-17T16:09:00.690 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2023-02-17T16:15:00.691 OK 2023-02-17T16:15:04.441 OK 20 TC(200,160) ZIA58726 SWA TC enter all sensor in Burst Mode 2023-02-17T17:27:30.699 OK 2023-02-17T17:27:32.450 OK 20 TC(200,160) ZIA58726 SWA TC enter all sensor in Burst Mode 2023-02-17T17:42:30.700 OK 2023-02-17T17:42:30.700 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2023-02-17T18:00:00.711 OK 2023-02-17T18:00:00.860 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2023-02-17T18:00:01.711 OK 2023-02-17T18:00:01.712 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2023-02-17T18:00:10.711 OK 2023-02-17T18:00:10.711 OK 4 TC(203,157) ZIA58943 SWA TC PAS start science 2023-02-17T18:01:50.730 OK 2023-02-17T18:01:50.731 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2023-02-17T18:02:10.711 OK 2023-02-17T18:02:12.586 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control Number of TC = 28 Number of TARS = 28 Number of TARF = 0 Number of TECS = 28 Number of TECF = 0 Number unacked = 0 Unknown TARF = 0 Unknown TECF = 0 Dupicate TARSF = 9 Dupicate TECSF = 9