============================================== TELECOMMANDS for 2023-03-30 ============================================== TC acceptation and status TC execution and status Size Service ID Label --------------------------- --------------------------- ---- ----------- -------- ----- 2023-03-30T00:00:00.729 OK 2023-03-30T00:00:00.876 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2023-03-30T00:00:01.730 OK 2023-03-30T00:00:01.731 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2023-03-30T00:00:10.729 OK 2023-03-30T00:00:10.729 OK 4 TC(203,157) ZIA58943 SWA TC PAS start science 2023-03-30T00:01:50.729 OK 2023-03-30T00:01:50.730 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2023-03-30T00:02:10.729 OK 2023-03-30T00:02:14.732 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2023-03-30T06:00:00.644 OK 2023-03-30T06:00:00.915 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2023-03-30T06:00:01.645 OK 2023-03-30T06:00:01.646 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2023-03-30T06:00:10.644 OK 2023-03-30T06:00:10.644 OK 4 TC(203,157) ZIA58943 SWA TC PAS start science 2023-03-30T06:01:50.644 OK 2023-03-30T06:01:50.645 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2023-03-30T06:02:10.644 OK 2023-03-30T06:02:10.768 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2023-03-30T08:00:00.645 OK 2023-03-30T08:00:00.645 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2023-03-30T08:06:00.651 OK 2023-03-30T08:06:00.777 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2023-03-30T08:06:02.656 OK 2023-03-30T08:06:02.777 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2023-03-30T08:06:04.658 OK 2023-03-30T08:06:04.658 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2023-03-30T08:06:05.654 OK 2023-03-30T08:06:05.655 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2023-03-30T08:06:06.647 OK 2023-03-30T08:06:15.022 OK 66 TC(201,173) ZIA58797 SWA TC EAS1 set preamp control data 2023-03-30T08:06:17.648 OK 2023-03-30T08:06:26.022 OK 66 TC(202,173) ZIA58845 SWA TC EAS2 set preamp control data 2023-03-30T08:06:28.646 OK 2023-03-30T08:06:28.646 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2023-03-30T08:06:29.646 OK 2023-03-30T08:06:29.646 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2023-03-30T08:06:30.646 OK 2023-03-30T08:06:30.646 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2023-03-30T08:06:31.647 OK 2023-03-30T08:11:41.648 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2023-03-30T08:06:32.648 OK 2023-03-30T08:12:11.275 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2023-03-30T08:13:32.648 OK 2023-03-30T08:19:11.149 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2023-03-30T08:13:33.649 OK 2023-03-30T08:18:43.525 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2023-03-30T08:20:33.649 OK 2023-03-30T08:25:43.525 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2023-03-30T08:20:34.649 OK 2023-03-30T08:26:13.149 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2023-03-30T08:27:34.649 OK 2023-03-30T08:33:13.150 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2023-03-30T08:27:35.650 OK 2023-03-30T08:32:45.526 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2023-03-30T08:34:35.649 OK 2023-03-30T08:34:35.649 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2023-03-30T08:34:36.649 OK 2023-03-30T08:34:36.649 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2023-03-30T08:34:37.649 OK 2023-03-30T08:34:37.649 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2023-03-30T08:35:28.650 OK 2023-03-30T08:35:37.025 OK 66 TC(201,173) ZIA58797 SWA TC EAS1 set preamp control data 2023-03-30T08:35:39.651 OK 2023-03-30T08:35:48.025 OK 66 TC(202,173) ZIA58845 SWA TC EAS2 set preamp control data 2023-03-30T08:35:50.650 OK 2023-03-30T08:35:50.776 OK 6 TC(201,142) ZIA58766 SWA TC EAS1 Set Hemisphere Voltage Ratio 2023-03-30T08:35:52.650 OK 2023-03-30T08:35:52.776 OK 6 TC(201,143) ZIA58767 SWA TC EAS1 Set Hemisphere High Voltage 2023-03-30T08:35:54.650 OK 2023-03-30T08:35:54.776 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2023-03-30T08:35:56.651 OK 2023-03-30T08:35:56.776 OK 6 TC(202,142) ZIA58814 SWA TC EAS2 Set Hemisphere Voltage Ratio 2023-03-30T08:35:58.651 OK 2023-03-30T08:35:58.776 OK 6 TC(202,143) ZIA58815 SWA TC EAS2 Set Hemisphere High Voltage 2023-03-30T08:36:00.651 OK 2023-03-30T08:36:00.776 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2023-03-30T08:36:02.652 OK 2023-03-30T08:36:02.653 OK 14 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2023-03-30T08:36:04.651 OK 2023-03-30T08:36:04.652 OK 14 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2023-03-30T08:36:06.650 OK 2023-03-30T08:36:06.776 OK 4 TC(201,160) ZIA58784 SWA TC EAS1 Set New HV for MCP 2023-03-30T08:36:07.650 OK 2023-03-30T08:36:07.776 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2023-03-30T08:36:08.650 OK 2023-03-30T08:36:08.776 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2023-03-30T08:36:09.650 OK 2023-03-30T08:36:09.776 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2023-03-30T08:36:11.651 OK 2023-03-30T08:36:11.776 OK 4 TC(202,160) ZIA58832 SWA TC EAS2 Set New HV for MCP 2023-03-30T08:36:12.651 OK 2023-03-30T08:36:12.776 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2023-03-30T08:36:13.651 OK 2023-03-30T08:36:13.776 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2023-03-30T08:36:14.651 OK 2023-03-30T08:36:14.776 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2023-03-30T08:36:16.650 OK 2023-03-30T08:36:16.776 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2023-03-30T08:36:18.655 OK 2023-03-30T08:36:18.780 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2023-03-30T08:42:18.650 OK 2023-03-30T08:42:18.650 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2023-03-30T11:53:50.670 OK 2023-03-30T11:53:50.671 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2023-03-30T11:59:50.683 OK 2023-03-30T11:59:50.683 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2023-03-30T12:00:00.683 OK 2023-03-30T12:08:49.688 OK 22 TC(203,128) ZIA58850 SWA TC PAS enter in Calibration mode 2023-03-30T12:10:11.708 OK 2023-03-30T12:10:11.709 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2023-03-30T12:10:31.685 OK 2023-03-30T12:10:34.816 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2023-03-30T12:10:40.672 OK 2023-03-30T12:10:40.672 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2023-03-30T17:21:30.706 OK 2023-03-30T17:21:30.706 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2023-03-30T17:27:30.706 OK 2023-03-30T17:27:30.708 OK 20 TC(200,160) ZIA58726 SWA TC enter all sensor in Burst Mode 2023-03-30T17:42:30.708 OK 2023-03-30T17:42:30.708 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2023-03-30T18:00:00.721 OK 2023-03-30T18:00:00.992 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2023-03-30T18:00:01.722 OK 2023-03-30T18:00:01.723 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2023-03-30T18:00:10.727 OK 2023-03-30T18:00:10.728 OK 4 TC(203,157) ZIA58943 SWA TC PAS start science 2023-03-30T18:01:50.722 OK 2023-03-30T18:01:50.722 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2023-03-30T18:02:10.721 OK 2023-03-30T18:02:10.845 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control Number of TC = 66 Number of TARS = 66 Number of TARF = 0 Number of TECS = 66 Number of TECF = 0 Number unacked = 0 Unknown TARF = 0 Unknown TECF = 0 Dupicate TARSF = 48 Dupicate TECSF = 48