============================================== TELECOMMANDS for 2024-05-22 ============================================== TC acceptation and status TC execution and status Size Service ID Label --------------------------- --------------------------- ---- ----------- -------- ----- 2024-05-22T11:54:00.683 OK 2024-05-22T11:54:00.683 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2024-05-22T11:59:40.684 OK 2024-05-22T11:59:40.684 OK 50 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2024-05-22T11:59:42.684 OK 2024-05-22T11:59:42.684 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2024-05-22T11:59:43.684 OK 2024-05-22T11:59:43.684 OK 6 TC(200,134) ZIA58707 SWA TC report configuration parameters 2024-05-22T12:01:01.697 OK 2024-05-22T12:01:01.697 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2024-05-22T12:01:11.696 OK 2024-05-22T12:10:02.698 OK 22 TC(203,128) ZIA58850 SWA TC PAS enter in Calibration mode 2024-05-22T12:11:11.685 OK 2024-05-22T12:11:11.685 OK 50 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2024-05-22T12:11:13.685 OK 2024-05-22T12:11:13.685 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2024-05-22T12:11:14.685 OK 2024-05-22T12:11:14.685 OK 6 TC(200,134) ZIA58707 SWA TC report configuration parameters 2024-05-22T12:12:00.685 OK 2024-05-22T12:12:00.685 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2024-05-22T12:30:00.693 OK 2024-05-22T12:35:01.942 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2024-05-22T12:30:01.697 OK 2024-05-22T12:35:03.071 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2024-05-22T13:00:00.696 OK 2024-05-22T13:05:01.945 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2024-05-22T13:00:01.700 OK 2024-05-22T13:05:03.074 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2024-05-22T14:00:00.702 OK 2024-05-22T14:05:01.952 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2024-05-22T14:00:01.707 OK 2024-05-22T14:05:03.081 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2024-05-22T15:00:00.709 OK 2024-05-22T15:05:01.958 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2024-05-22T15:00:01.713 OK 2024-05-22T15:05:03.087 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2024-05-22T16:00:00.716 OK 2024-05-22T16:05:01.965 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2024-05-22T16:00:01.720 OK 2024-05-22T16:05:03.094 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2024-05-22T17:00:00.722 OK 2024-05-22T17:05:01.971 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2024-05-22T17:00:01.726 OK 2024-05-22T17:05:03.100 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2024-05-22T17:19:00.719 OK 2024-05-22T17:19:00.719 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2024-05-22T17:25:00.719 OK 2024-05-22T17:25:03.844 OK 20 TC(200,160) ZIA58726 SWA TC enter all sensor in Burst Mode 2024-05-22T17:40:00.721 OK 2024-05-22T17:40:00.721 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2024-05-22T18:00:00.729 OK 2024-05-22T18:05:01.978 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2024-05-22T18:00:01.733 OK 2024-05-22T18:05:03.107 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2024-05-22T19:00:00.735 OK 2024-05-22T19:05:01.984 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2024-05-22T19:00:01.739 OK 2024-05-22T19:05:03.113 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2024-05-22T20:00:00.742 OK 2024-05-22T20:05:01.991 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2024-05-22T20:00:01.746 OK 2024-05-22T20:05:03.120 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2024-05-22T21:00:00.749 OK 2024-05-22T21:05:01.997 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2024-05-22T21:00:01.753 OK 2024-05-22T21:05:03.126 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2024-05-22T22:00:00.631 OK 2024-05-22T22:05:01.004 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2024-05-22T22:00:01.638 OK 2024-05-22T22:05:02.133 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2024-05-22T23:00:00.638 OK 2024-05-22T23:05:01.010 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2024-05-22T23:00:01.645 OK 2024-05-22T23:05:02.139 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode Number of TC = 37 Number of TARS = 37 Number of TARF = 0 Number of TECS = 37 Number of TECF = 0 Number unacked = 0 Unknown TARF = 0 Unknown TECF = 0 Dupicate TARSF = 25 Dupicate TECSF = 25