============================================== TELECOMMANDS for 2025-02-19 ============================================== TC acceptation and status TC execution and status Size Service ID Label --------------------------- --------------------------- ---- ----------- -------- ----- 2025-02-19T02:04:35.638 OK 2025-02-19T02:04:35.639 OK 4 TC(200,165) ZIA58004 SWA TC enable/disable command to individual sensor 2025-02-19T02:04:37.639 OK 2025-02-19T02:04:37.639 OK 4 TC(200,176) ZIA58069 SWA TC reset the ERROR condition counters for the spec. Event 2025-02-19T02:04:39.639 OK 2025-02-19T02:04:39.639 OK 4 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2025-02-19T02:04:43.638 OK 2025-02-19T02:04:43.639 OK 4 TC(200,162) ZIA58728 SWA TC modify the cadence of sci data generation 2025-02-19T02:04:45.638 OK 2025-02-19T02:04:45.638 OK 50 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-02-19T02:04:47.638 OK 2025-02-19T02:04:47.638 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2025-02-19T02:04:48.638 OK 2025-02-19T02:04:48.638 OK 6 TC(200,134) ZIA58707 SWA TC report configuration parameters 2025-02-19T02:04:49.638 OK 2025-02-19T02:04:49.638 OK 50 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-02-19T02:04:51.638 OK 2025-02-19T02:04:51.638 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2025-02-19T02:04:52.638 OK 2025-02-19T02:04:52.638 OK 6 TC(200,134) ZIA58707 SWA TC report configuration parameters 2025-02-19T02:04:53.638 OK 2025-02-19T02:04:53.638 OK 38 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-02-19T02:04:55.638 OK 2025-02-19T02:04:55.638 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2025-02-19T02:04:56.638 OK 2025-02-19T02:04:56.638 OK 6 TC(200,134) ZIA58707 SWA TC report configuration parameters 2025-02-19T02:04:57.639 OK 2025-02-19T02:04:57.639 OK 31 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2025-02-19T02:04:58.639 OK 2025-02-19T02:04:58.639 OK 6 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2025-02-19T02:05:28.639 OK 2025-02-19T02:05:28.639 OK 4 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2025-02-19T02:05:29.639 OK 2025-02-19T02:05:29.639 OK 4 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2025-02-19T02:05:30.639 OK 2025-02-19T02:05:30.764 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-02-19T02:05:40.639 OK 2025-02-19T02:05:40.764 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-02-19T02:05:50.639 OK 2025-02-19T02:05:50.764 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-02-19T02:06:00.639 OK 2025-02-19T02:06:00.764 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-02-19T02:06:10.639 OK 2025-02-19T02:06:10.764 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-02-19T02:06:20.639 OK 2025-02-19T02:06:20.764 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-02-19T02:06:30.639 OK 2025-02-19T02:06:30.764 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-02-19T02:06:40.639 OK 2025-02-19T02:06:40.764 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-02-19T02:06:50.639 OK 2025-02-19T02:06:50.764 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-02-19T02:07:00.639 OK 2025-02-19T02:07:00.764 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-02-19T02:07:10.639 OK 2025-02-19T02:07:10.639 OK 5 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2025-02-19T02:07:40.639 OK 2025-02-19T02:07:40.763 OK 6 TC(203,141) ZIA58863 SWA TC PAS write Master Control register 2025-02-19T02:07:42.639 OK 2025-02-19T02:07:42.773 OK 6 TC(203,141) ZIA58863 SWA TC PAS write Master Control register 2025-02-19T02:07:44.639 OK 2025-02-19T02:07:44.763 OK 4 TC(203,140) ZIA58862 SWA TC PAS write Pre-Amp power Control register 2025-02-19T02:07:49.639 OK 2025-02-19T02:07:51.138 OK 24 TC(203,154) ZIA58876 SWA TC PAS Upload Static Table 2025-02-19T02:07:54.639 OK 2025-02-19T02:07:55.138 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2025-02-19T02:08:24.639 OK 2025-02-19T02:08:25.282 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2025-02-19T02:08:29.639 OK 2025-02-19T02:23:43.390 OK 10 TC(203,134) ZIA58856 PAS HV Ramp UP 2025-02-19T02:26:57.641 OK 2025-02-19T02:26:57.642 OK 18 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2025-02-19T02:28:52.641 OK 2025-02-19T02:28:52.642 OK 4 TC(203,157) ZIA58943 SWA TC PAS start science 2025-02-19T02:29:52.640 OK 2025-02-19T02:29:52.641 OK 50 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-02-19T02:29:54.640 OK 2025-02-19T02:29:54.641 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2025-02-19T02:29:55.640 OK 2025-02-19T02:29:55.641 OK 6 TC(200,134) ZIA58707 SWA TC report configuration parameters 2025-02-19T08:32:00.681 OK 2025-02-19T08:32:01.306 OK 2 TC(200,153) ZIA58729 SWA TC DPU switch ON HIS 2025-02-19T08:32:01.681 ERR -- 2 TC(200,153) ZIA58729 SWA TC DPU switch ON HIS 2025-02-19T08:32:44.808 OK 2025-02-19T08:32:44.808 OK 10 TC(204,176) ZIA58931 SWA TC HIS Set housekeeping collection interval for spec. SID 2025-02-19T08:33:19.808 OK 2025-02-19T08:33:19.808 OK 6 TC(204,145) ZIA58917 SWA TC HIS change mode -- -- 6 TC(204,145) ZIA58917 SWA TC HIS change mode 2025-02-19T08:37:30.809 OK 2025-02-19T08:37:30.935 OK 20 TC(204,148) ZIA58939 SWA TC HIS safety set 2025-02-19T08:38:00.807 OK 2025-02-19T08:38:00.932 OK 10 TC(204,147) ZIA58919 SWA TC HIS set parameters temporarily 2025-02-19T08:51:27.684 OK 2025-02-19T08:51:27.685 OK 4 TC( 3, 5) ZIA58050 SWA TC enable HK report generation 2025-02-19T08:51:29.684 OK 2025-02-19T08:51:29.685 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2025-02-19T08:51:30.684 OK 2025-02-19T08:51:32.808 OK 2 TC(201,136) ZIA58760 SWA TC EAS1 Power ON 2025-02-19T08:51:37.684 OK 2025-02-19T08:51:38.183 OK 4 TC(201,135) ZIA58934 SWA TC EAS1 start service macro 2025-02-19T08:51:42.684 OK 2025-02-19T08:51:46.308 OK 2 TC(201,129) ZIA58753 SWA TC EAS1 enter in idle mode 2025-02-19T08:52:12.685 OK 2025-02-19T08:52:12.809 OK 2 TC(201,158) ZIA58782 SWA TC EAS1 HK data Request 2025-02-19T08:52:14.685 OK 2025-02-19T08:52:25.058 OK 2 TC(201,134) ZIA58758 SWA TC EAS1 HV Ramp UP 2025-02-19T08:52:44.685 OK 2025-02-19T08:52:44.809 OK 6 TC(201,152) ZIA58776 SWA TC EAS1 Write Master Control Register 2025-02-19T08:52:46.685 OK 2025-02-19T08:52:46.809 OK 6 TC(201,133) ZIA58757 SWA TC EAS1 Sensor Reset 2025-02-19T08:52:48.685 OK 2025-02-19T08:52:48.809 OK 14 TC(201,145) ZIA58769 SWA TC EAS1 Set Analizer Voltage Offsets 2025-02-19T08:52:50.685 OK 2025-02-19T08:52:50.809 OK 6 TC(201,142) ZIA58766 SWA TC EAS1 Set Hemisphere Voltage Ratio 2025-02-19T08:52:52.685 OK 2025-02-19T08:52:52.809 OK 6 TC(201,143) ZIA58767 SWA TC EAS1 Set Hemisphere High Voltage 2025-02-19T08:52:54.686 OK 2025-02-19T08:52:54.809 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2025-02-19T08:52:56.686 OK 2025-02-19T08:53:05.059 OK 66 TC(201,173) ZIA58797 SWA TC EAS1 set preamp control data 2025-02-19T08:53:06.686 OK 2025-02-19T08:53:06.809 OK 4 TC(201,160) ZIA58784 SWA TC EAS1 Set New HV for MCP 2025-02-19T08:53:36.683 OK 2025-02-19T08:53:36.683 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-02-19T08:53:38.683 OK 2025-02-19T08:53:38.683 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2025-02-19T08:53:40.686 OK 2025-02-19T08:53:40.686 OK 4 TC(201,172) ZIA58796 SWA TC EAS1 extract sthral energy 2025-02-19T08:54:37.688 OK 2025-02-19T08:54:37.688 OK 14 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2025-02-19T08:54:39.686 OK 2025-02-19T08:54:39.687 OK 4 TC( 3, 5) ZIA58050 SWA TC enable HK report generation 2025-02-19T08:54:41.687 OK 2025-02-19T08:54:41.688 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2025-02-19T08:54:42.686 OK 2025-02-19T08:54:44.810 OK 2 TC(202,136) ZIA58808 SWA TC EAS2 Power ON 2025-02-19T08:54:49.686 OK 2025-02-19T08:54:50.184 OK 4 TC(202,135) ZIA58936 SWA TC EAS2 start service macro 2025-02-19T08:54:54.686 OK 2025-02-19T08:54:58.309 OK 2 TC(202,129) ZIA58801 SWA TC EAS2 enter in idle mode 2025-02-19T08:55:24.700 OK 2025-02-19T08:55:24.810 OK 2 TC(202,158) ZIA58830 SWA TC EAS2 HK data Request 2025-02-19T08:55:26.686 OK 2025-02-19T08:55:37.059 OK 2 TC(202,134) ZIA58806 SWA TC EAS2 HV Ramp UP 2025-02-19T08:55:56.687 OK 2025-02-19T08:55:56.811 OK 6 TC(202,152) ZIA58824 SWA TC EAS2 Write Master Control Register 2025-02-19T08:55:58.687 OK 2025-02-19T08:55:58.811 OK 6 TC(202,133) ZIA58805 SWA TC EAS2 Sensor Reset 2025-02-19T08:56:00.687 OK 2025-02-19T08:56:00.811 OK 14 TC(202,145) ZIA58817 SWA TC EAS2 Set Analizer Voltage Offsets 2025-02-19T08:56:02.687 OK 2025-02-19T08:56:02.811 OK 6 TC(202,142) ZIA58814 SWA TC EAS2 Set Hemisphere Voltage Ratio 2025-02-19T08:56:04.687 OK 2025-02-19T08:56:04.811 OK 6 TC(202,143) ZIA58815 SWA TC EAS2 Set Hemisphere High Voltage 2025-02-19T08:56:06.687 OK 2025-02-19T08:56:06.811 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2025-02-19T08:56:08.687 OK 2025-02-19T08:56:17.060 OK 66 TC(202,173) ZIA58845 SWA TC EAS2 set preamp control data 2025-02-19T08:56:18.687 OK 2025-02-19T08:56:18.811 OK 4 TC(202,160) ZIA58832 SWA TC EAS2 Set New HV for MCP 2025-02-19T08:56:48.684 OK 2025-02-19T08:56:48.684 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-02-19T08:56:50.684 OK 2025-02-19T08:56:50.684 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2025-02-19T08:56:52.687 OK 2025-02-19T08:56:52.688 OK 4 TC(202,172) ZIA58844 SWA TC EAS2 extract sthral energy 2025-02-19T08:57:49.688 OK 2025-02-19T08:57:49.688 OK 14 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2025-02-19T08:57:51.684 OK 2025-02-19T08:57:52.434 OK 4 TC(200,141) ZIA58737 SWA TC initialize DPU SDP configuration 2025-02-19T08:57:55.687 OK 2025-02-19T08:57:55.810 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2025-02-19T08:57:57.691 OK 2025-02-19T08:57:57.816 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2025-02-19T09:02:57.688 OK 2025-02-19T09:02:57.688 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2025-02-19T10:40:00.698 OK 2025-02-19T10:40:00.698 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2025-02-19T10:46:00.704 OK 2025-02-19T10:46:00.830 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2025-02-19T10:46:02.703 OK 2025-02-19T10:46:02.829 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2025-02-19T10:46:04.700 OK 2025-02-19T10:46:04.700 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2025-02-19T10:46:05.700 OK 2025-02-19T10:46:05.700 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2025-02-19T10:46:06.699 OK 2025-02-19T10:46:15.072 OK 66 TC(201,173) ZIA58797 SWA TC EAS1 set preamp control data 2025-02-19T10:46:17.700 OK 2025-02-19T10:46:26.072 OK 66 TC(202,173) ZIA58845 SWA TC EAS2 set preamp control data 2025-02-19T10:46:28.696 OK 2025-02-19T10:46:28.696 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-02-19T10:46:29.696 OK 2025-02-19T10:46:29.696 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-02-19T10:46:30.696 OK 2025-02-19T10:46:30.696 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2025-02-19T10:46:31.699 OK 2025-02-19T10:51:42.450 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2025-02-19T10:46:32.700 OK 2025-02-19T10:52:11.323 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2025-02-19T10:53:32.700 OK 2025-02-19T10:59:11.198 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2025-02-19T10:53:33.700 OK 2025-02-19T10:58:44.324 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2025-02-19T11:00:33.700 OK 2025-02-19T11:05:44.324 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2025-02-19T11:00:34.701 OK 2025-02-19T11:06:13.199 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2025-02-19T11:07:34.721 OK 2025-02-19T11:13:13.325 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2025-02-19T11:07:35.702 OK 2025-02-19T11:12:46.200 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2025-02-19T11:14:35.699 OK 2025-02-19T11:14:35.699 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-02-19T11:14:36.699 OK 2025-02-19T11:14:36.699 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-02-19T11:14:37.699 OK 2025-02-19T11:14:37.699 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2025-02-19T11:15:28.702 OK 2025-02-19T11:15:37.075 OK 66 TC(201,173) ZIA58797 SWA TC EAS1 set preamp control data 2025-02-19T11:15:39.723 OK 2025-02-19T11:15:48.076 OK 66 TC(202,173) ZIA58845 SWA TC EAS2 set preamp control data 2025-02-19T11:15:50.702 OK 2025-02-19T11:15:50.826 OK 6 TC(201,142) ZIA58766 SWA TC EAS1 Set Hemisphere Voltage Ratio 2025-02-19T11:15:52.702 OK 2025-02-19T11:15:52.826 OK 6 TC(201,143) ZIA58767 SWA TC EAS1 Set Hemisphere High Voltage 2025-02-19T11:15:54.702 OK 2025-02-19T11:15:54.826 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2025-02-19T11:15:56.703 OK 2025-02-19T11:15:56.826 OK 6 TC(202,142) ZIA58814 SWA TC EAS2 Set Hemisphere Voltage Ratio 2025-02-19T11:15:58.703 OK 2025-02-19T11:15:58.826 OK 6 TC(202,143) ZIA58815 SWA TC EAS2 Set Hemisphere High Voltage 2025-02-19T11:16:00.703 OK 2025-02-19T11:16:00.826 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2025-02-19T11:16:02.704 OK 2025-02-19T11:16:02.705 OK 14 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2025-02-19T11:16:04.703 OK 2025-02-19T11:16:04.703 OK 14 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2025-02-19T11:16:06.702 OK 2025-02-19T11:16:06.839 OK 4 TC(201,160) ZIA58784 SWA TC EAS1 Set New HV for MCP 2025-02-19T11:16:07.702 OK 2025-02-19T11:16:07.826 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2025-02-19T11:16:08.702 OK 2025-02-19T11:16:08.826 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2025-02-19T11:16:09.702 OK 2025-02-19T11:16:09.826 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2025-02-19T11:16:11.703 OK 2025-02-19T11:16:11.826 OK 4 TC(202,160) ZIA58832 SWA TC EAS2 Set New HV for MCP 2025-02-19T11:16:12.703 OK 2025-02-19T11:16:12.826 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2025-02-19T11:16:13.703 OK 2025-02-19T11:16:13.826 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2025-02-19T11:16:14.703 OK 2025-02-19T11:16:14.826 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2025-02-19T11:16:16.702 OK 2025-02-19T11:16:16.826 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2025-02-19T11:16:18.707 OK 2025-02-19T11:16:18.831 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2025-02-19T11:21:18.703 OK 2025-02-19T11:21:18.703 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2025-02-19T11:40:00.710 OK 2025-02-19T11:45:01.207 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T11:40:01.714 OK 2025-02-19T11:45:02.336 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T11:54:00.707 OK 2025-02-19T11:54:00.707 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2025-02-19T12:00:40.707 OK 2025-02-19T12:00:40.708 OK 50 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-02-19T12:00:42.707 OK 2025-02-19T12:00:42.707 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2025-02-19T12:00:43.707 OK 2025-02-19T12:00:43.708 OK 6 TC(200,134) ZIA58707 SWA TC report configuration parameters 2025-02-19T12:01:41.718 OK 2025-02-19T12:01:41.718 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2025-02-19T12:01:51.716 OK 2025-02-19T12:10:41.969 OK 22 TC(203,128) ZIA58850 SWA TC PAS enter in Calibration mode 2025-02-19T12:11:51.708 OK 2025-02-19T12:11:51.709 OK 50 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-02-19T12:11:53.708 OK 2025-02-19T12:11:53.709 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2025-02-19T12:11:54.708 OK 2025-02-19T12:11:54.709 OK 6 TC(200,134) ZIA58707 SWA TC report configuration parameters 2025-02-19T12:11:55.708 OK 2025-02-19T12:11:55.708 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2025-02-19T12:20:00.715 OK 2025-02-19T12:25:01.211 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T12:20:01.719 OK 2025-02-19T12:25:02.340 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T12:30:00.716 OK 2025-02-19T12:35:01.212 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T12:30:01.741 OK 2025-02-19T12:35:02.342 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T12:40:00.717 OK 2025-02-19T12:45:01.213 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T12:40:01.720 OK 2025-02-19T12:45:02.343 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T13:00:00.719 OK 2025-02-19T13:05:01.216 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T13:00:01.723 OK 2025-02-19T13:05:02.364 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T13:20:00.722 OK 2025-02-19T13:25:01.218 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T13:20:01.726 OK 2025-02-19T13:25:02.347 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T13:40:00.724 OK 2025-02-19T13:45:01.220 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T13:40:01.728 OK 2025-02-19T13:45:02.349 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T14:00:00.726 OK 2025-02-19T14:05:01.222 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T14:00:01.730 OK 2025-02-19T14:05:02.351 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T14:20:00.728 OK 2025-02-19T14:25:01.225 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T14:20:01.732 OK 2025-02-19T14:25:02.353 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T14:40:00.730 OK 2025-02-19T14:45:01.227 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T14:40:01.734 OK 2025-02-19T14:45:02.356 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T15:00:00.732 OK 2025-02-19T15:05:01.238 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T15:00:01.736 OK 2025-02-19T15:05:02.358 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T15:20:00.735 OK 2025-02-19T15:25:01.231 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T15:20:01.739 OK 2025-02-19T15:25:02.360 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T15:40:00.737 OK 2025-02-19T15:45:01.233 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T15:40:01.741 OK 2025-02-19T15:45:02.362 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T16:00:00.739 OK 2025-02-19T16:05:01.236 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T16:00:01.743 OK 2025-02-19T16:05:02.365 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T16:20:00.741 OK 2025-02-19T16:25:01.238 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T16:20:01.745 OK 2025-02-19T16:25:02.367 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T16:40:00.744 OK 2025-02-19T16:45:01.240 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T16:40:01.748 OK 2025-02-19T16:45:02.369 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T17:00:00.768 OK 2025-02-19T17:05:01.242 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T17:00:01.750 OK 2025-02-19T17:05:02.371 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T17:19:00.742 OK 2025-02-19T17:19:00.742 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2025-02-19T17:25:00.744 OK 2025-02-19T17:25:03.115 OK 20 TC(200,160) ZIA58726 SWA TC enter all sensor in Burst Mode 2025-02-19T17:40:00.744 OK 2025-02-19T17:40:00.744 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2025-02-19T18:00:00.752 OK 2025-02-19T18:05:01.249 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T18:00:01.756 OK 2025-02-19T18:05:02.378 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T18:20:00.640 OK 2025-02-19T18:25:01.251 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T18:20:01.660 OK 2025-02-19T18:25:02.380 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T18:40:00.643 OK 2025-02-19T18:45:01.253 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T18:40:01.664 OK 2025-02-19T18:45:02.382 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T19:00:00.645 OK 2025-02-19T19:05:01.255 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T19:00:01.666 OK 2025-02-19T19:05:02.385 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T19:20:00.647 OK 2025-02-19T19:25:01.258 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T19:20:01.666 OK 2025-02-19T19:25:02.387 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T19:40:00.668 OK 2025-02-19T19:45:01.260 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T19:40:01.699 OK 2025-02-19T19:45:02.389 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T20:00:00.651 OK 2025-02-19T20:05:01.262 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T20:00:01.672 OK 2025-02-19T20:05:02.391 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T20:20:00.654 OK 2025-02-19T20:25:01.264 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T20:20:01.702 OK 2025-02-19T20:25:02.393 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T20:40:00.656 OK 2025-02-19T20:45:01.266 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T20:40:01.677 OK 2025-02-19T20:45:02.396 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T21:00:00.658 OK 2025-02-19T21:05:01.269 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T21:00:01.682 OK 2025-02-19T21:05:02.398 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T21:20:00.660 OK 2025-02-19T21:25:01.271 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T21:20:01.680 OK 2025-02-19T21:25:02.400 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T21:40:00.663 OK 2025-02-19T21:45:01.273 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T21:40:01.684 OK 2025-02-19T21:45:02.402 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T22:00:00.665 OK 2025-02-19T22:05:01.275 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T22:00:01.686 OK 2025-02-19T22:05:02.405 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T22:20:00.667 OK 2025-02-19T22:25:01.278 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T22:20:01.686 OK 2025-02-19T22:25:02.407 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T22:40:00.669 OK 2025-02-19T22:45:01.280 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T22:40:01.690 OK 2025-02-19T22:45:02.409 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T23:00:00.671 OK 2025-02-19T23:05:01.282 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T23:00:01.693 OK 2025-02-19T23:05:02.411 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T23:20:00.674 OK 2025-02-19T23:25:01.284 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T23:20:01.693 OK 2025-02-19T23:25:02.413 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-02-19T23:40:00.676 OK 2025-02-19T23:45:01.286 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-02-19T23:40:01.697 OK 2025-02-19T23:45:02.416 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode Number of TC = 214 Number of TARS = 212 Number of TARF = 1 Number of TECS = 212 Number of TECF = 0 Number unacked = 1 Unknown TARF = 0 Unknown TECF = 0 Dupicate TARSF = 118 Dupicate TECSF = 120