============================================== TELECOMMANDS for 2025-08-25 ============================================== TC acceptation and status TC execution and status Size Service ID Label --------------------------- --------------------------- ---- ----------- -------- ----- 2025-08-25T03:05:00.692 OK 2025-08-25T03:05:00.692 OK 4 TC(200,165) ZIA58004 SWA TC enable/disable command to individual sensor 2025-08-25T03:05:02.694 OK 2025-08-25T03:05:02.694 OK 4 TC(200,176) ZIA58069 SWA TC reset the ERROR condition counters for the spec. Event 2025-08-25T03:05:04.694 OK 2025-08-25T03:05:04.694 OK 4 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2025-08-25T03:05:08.692 OK 2025-08-25T03:05:08.692 OK 4 TC(200,162) ZIA58728 SWA TC modify the cadence of sci data generation 2025-08-25T03:05:10.690 OK 2025-08-25T03:05:10.690 OK 50 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-08-25T03:05:12.690 OK 2025-08-25T03:05:12.690 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2025-08-25T03:05:13.690 OK 2025-08-25T03:05:13.691 OK 6 TC(200,134) ZIA58707 SWA TC report configuration parameters 2025-08-25T03:05:14.690 OK 2025-08-25T03:05:14.690 OK 50 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-08-25T03:05:16.690 OK 2025-08-25T03:05:16.690 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2025-08-25T03:05:17.690 OK 2025-08-25T03:05:17.691 OK 6 TC(200,134) ZIA58707 SWA TC report configuration parameters 2025-08-25T03:05:18.690 OK 2025-08-25T03:05:18.690 OK 38 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-08-25T03:05:20.690 OK 2025-08-25T03:05:20.690 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2025-08-25T03:05:21.690 OK 2025-08-25T03:05:21.691 OK 6 TC(200,134) ZIA58707 SWA TC report configuration parameters 2025-08-25T03:05:22.694 OK 2025-08-25T03:05:22.695 OK 31 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2025-08-25T03:05:23.694 OK 2025-08-25T03:05:23.695 OK 6 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2025-08-25T03:05:53.694 OK 2025-08-25T03:05:53.695 OK 4 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2025-08-25T03:05:54.694 OK 2025-08-25T03:05:54.695 OK 4 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2025-08-25T03:05:55.694 OK 2025-08-25T03:05:55.818 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-08-25T03:06:05.694 OK 2025-08-25T03:06:05.818 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-08-25T03:06:15.694 OK 2025-08-25T03:06:15.818 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-08-25T03:06:25.694 OK 2025-08-25T03:06:25.818 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-08-25T03:06:35.694 OK 2025-08-25T03:06:35.818 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-08-25T03:06:45.694 OK 2025-08-25T03:06:45.818 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-08-25T03:06:55.694 OK 2025-08-25T03:06:55.818 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-08-25T03:07:05.694 OK 2025-08-25T03:07:05.821 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-08-25T03:07:15.694 OK 2025-08-25T03:07:15.818 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-08-25T03:07:25.694 OK 2025-08-25T03:07:25.818 OK 6 TC(203,147) ZIA58869 SWA TC PAS Set Main HV 2025-08-25T03:07:35.694 OK 2025-08-25T03:07:35.695 OK 5 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2025-08-25T03:08:05.694 OK 2025-08-25T03:08:05.817 OK 6 TC(203,141) ZIA58863 SWA TC PAS write Master Control register 2025-08-25T03:08:07.694 OK 2025-08-25T03:08:07.817 OK 6 TC(203,141) ZIA58863 SWA TC PAS write Master Control register 2025-08-25T03:08:09.694 OK 2025-08-25T03:08:09.817 OK 4 TC(203,140) ZIA58862 SWA TC PAS write Pre-Amp power Control register 2025-08-25T03:08:14.695 OK 2025-08-25T03:08:17.192 OK 24 TC(203,154) ZIA58876 SWA TC PAS Upload Static Table 2025-08-25T03:08:19.694 OK 2025-08-25T03:08:21.192 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2025-08-25T03:08:49.694 OK 2025-08-25T03:08:49.817 OK 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control 2025-08-25T03:08:54.695 OK 2025-08-25T03:24:59.194 OK 10 TC(203,134) ZIA58856 PAS HV Ramp UP 2025-08-25T03:28:22.697 OK 2025-08-25T03:28:22.697 OK 18 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2025-08-25T03:30:31.697 OK 2025-08-25T03:30:31.697 OK 4 TC(203,157) ZIA58943 SWA TC PAS start science 2025-08-25T03:32:01.693 OK 2025-08-25T03:32:01.693 OK 50 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-08-25T03:32:03.693 OK 2025-08-25T03:32:03.693 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2025-08-25T03:32:04.693 OK 2025-08-25T03:32:04.694 OK 6 TC(200,134) ZIA58707 SWA TC report configuration parameters 2025-08-25T04:05:02.700 OK 2025-08-25T04:05:02.824 OK 4 TC(201,160) ZIA58784 SWA TC EAS1 Set New HV for MCP 2025-08-25T04:05:03.700 OK 2025-08-25T04:05:03.824 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2025-08-25T04:05:04.700 OK 2025-08-25T04:05:04.824 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2025-08-25T04:05:05.700 OK 2025-08-25T04:05:05.824 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2025-08-25T04:05:07.700 OK 2025-08-25T04:05:07.824 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2025-08-25T04:05:09.704 OK 2025-08-25T04:05:09.829 OK 4 TC(202,160) ZIA58832 SWA TC EAS2 Set New HV for MCP 2025-08-25T04:05:10.704 OK 2025-08-25T04:05:10.829 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2025-08-25T04:05:11.705 OK 2025-08-25T04:05:11.829 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2025-08-25T04:05:12.704 OK 2025-08-25T04:05:12.829 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2025-08-25T04:05:14.715 OK 2025-08-25T04:05:14.829 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2025-08-25T04:10:14.700 OK 2025-08-25T04:10:14.701 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2025-08-25T05:00:00.712 OK 2025-08-25T05:05:01.208 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T05:00:01.716 OK 2025-08-25T05:05:02.338 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T05:20:00.732 OK 2025-08-25T05:20:00.732 ERR 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T05:20:01.718 OK 2025-08-25T05:20:01.718 ERR 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T05:30:00.709 OK 2025-08-25T05:30:00.709 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2025-08-25T05:36:00.716 OK 2025-08-25T05:36:00.841 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2025-08-25T05:36:02.715 OK 2025-08-25T05:36:02.840 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2025-08-25T05:36:04.712 OK 2025-08-25T05:36:04.712 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2025-08-25T05:36:05.711 OK 2025-08-25T05:36:05.711 OK 15 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters 2025-08-25T05:36:06.710 OK 2025-08-25T05:36:15.083 OK 66 TC(201,173) ZIA58797 SWA TC EAS1 set preamp control data 2025-08-25T05:36:17.711 OK 2025-08-25T05:36:26.084 OK 66 TC(202,173) ZIA58845 SWA TC EAS2 set preamp control data 2025-08-25T05:36:28.707 OK 2025-08-25T05:36:28.707 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-08-25T05:36:29.707 OK 2025-08-25T05:36:29.707 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-08-25T05:36:30.707 OK 2025-08-25T05:36:30.707 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2025-08-25T05:36:31.710 OK 2025-08-25T05:41:42.459 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2025-08-25T05:36:32.711 OK 2025-08-25T05:42:11.334 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2025-08-25T05:43:32.711 OK 2025-08-25T05:49:11.210 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2025-08-25T05:43:33.711 OK 2025-08-25T05:48:44.335 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2025-08-25T05:50:33.712 OK 2025-08-25T05:55:44.210 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2025-08-25T05:50:34.712 OK 2025-08-25T05:56:13.336 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2025-08-25T05:57:34.713 OK 2025-08-25T06:03:13.211 OK 14 TC(201,165) ZIA58789 SWA TC EAS1 enter in engineering 3 mode 2025-08-25T05:57:35.727 OK 2025-08-25T06:02:46.337 OK 14 TC(202,165) ZIA58837 SWA TC EAS2 enter in engineering 3 mode 2025-08-25T06:04:35.710 OK 2025-08-25T06:04:35.710 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-08-25T06:04:36.710 OK 2025-08-25T06:04:36.710 OK 14 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-08-25T06:04:37.710 OK 2025-08-25T06:04:37.710 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2025-08-25T06:05:28.713 OK 2025-08-25T06:05:37.087 OK 66 TC(201,173) ZIA58797 SWA TC EAS1 set preamp control data 2025-08-25T06:05:39.714 OK 2025-08-25T06:05:48.087 OK 66 TC(202,173) ZIA58845 SWA TC EAS2 set preamp control data 2025-08-25T06:05:50.713 OK 2025-08-25T06:05:50.837 OK 6 TC(201,142) ZIA58766 SWA TC EAS1 Set Hemisphere Voltage Ratio 2025-08-25T06:05:52.713 OK 2025-08-25T06:05:52.837 OK 6 TC(201,143) ZIA58767 SWA TC EAS1 Set Hemisphere High Voltage 2025-08-25T06:05:54.713 OK 2025-08-25T06:05:54.837 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2025-08-25T06:05:56.714 OK 2025-08-25T06:05:56.838 OK 6 TC(202,142) ZIA58814 SWA TC EAS2 Set Hemisphere Voltage Ratio 2025-08-25T06:05:58.714 OK 2025-08-25T06:05:58.838 OK 6 TC(202,143) ZIA58815 SWA TC EAS2 Set Hemisphere High Voltage 2025-08-25T06:06:00.714 OK 2025-08-25T06:06:00.838 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2025-08-25T06:06:02.714 OK 2025-08-25T06:06:02.715 OK 14 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2025-08-25T06:06:04.720 OK 2025-08-25T06:06:04.721 OK 14 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters 2025-08-25T06:06:06.713 OK 2025-08-25T06:06:06.837 OK 4 TC(201,160) ZIA58784 SWA TC EAS1 Set New HV for MCP 2025-08-25T06:06:07.713 OK 2025-08-25T06:06:07.846 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2025-08-25T06:06:08.713 OK 2025-08-25T06:06:08.837 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2025-08-25T06:06:09.713 OK 2025-08-25T06:06:09.837 OK 4 TC(201,161) ZIA58785 SWA TC EAS1 Dump Parameter 2025-08-25T06:06:11.714 OK 2025-08-25T06:06:11.838 OK 4 TC(202,160) ZIA58832 SWA TC EAS2 Set New HV for MCP 2025-08-25T06:06:12.714 OK 2025-08-25T06:06:12.838 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2025-08-25T06:06:13.714 OK 2025-08-25T06:06:13.838 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2025-08-25T06:06:14.714 OK 2025-08-25T06:06:14.838 OK 4 TC(202,161) ZIA58833 SWA TC EAS2 Dump Parameter 2025-08-25T06:06:16.713 OK 2025-08-25T06:06:16.837 OK 6 TC(201,147) ZIA58771 SWA TC EAS1 Write Mailbox control 2025-08-25T06:06:18.718 OK 2025-08-25T06:06:18.843 OK 6 TC(202,147) ZIA58819 SWA TC EAS2 Write Mailbox control 2025-08-25T06:11:18.714 OK 2025-08-25T06:11:18.714 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2025-08-25T06:20:00.720 OK 2025-08-25T06:25:01.217 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T06:20:01.724 OK 2025-08-25T06:25:02.346 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T06:40:00.722 OK 2025-08-25T06:45:01.219 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T06:40:01.740 OK 2025-08-25T06:45:02.349 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T07:00:00.725 OK 2025-08-25T07:05:01.222 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T07:00:01.729 OK 2025-08-25T07:05:02.351 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T07:20:00.727 OK 2025-08-25T07:25:01.224 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T07:20:01.731 OK 2025-08-25T07:25:02.353 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T07:40:00.729 OK 2025-08-25T07:40:00.729 ERR 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T07:40:01.733 OK 2025-08-25T07:40:01.733 ERR 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T08:00:00.731 OK 2025-08-25T08:05:01.228 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T08:00:01.735 OK 2025-08-25T08:05:02.358 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T08:20:00.734 OK 2025-08-25T08:25:01.231 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T08:20:01.738 OK 2025-08-25T08:25:02.360 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T08:40:00.736 OK 2025-08-25T08:45:01.233 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T08:40:01.740 OK 2025-08-25T08:45:02.362 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T09:00:00.737 OK 2025-08-25T09:05:01.235 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T09:00:01.742 OK 2025-08-25T09:05:02.364 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T09:20:00.741 OK 2025-08-25T09:25:01.237 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T09:20:01.744 OK 2025-08-25T09:25:02.371 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T09:40:00.743 OK 2025-08-25T09:45:01.240 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T09:40:01.747 OK 2025-08-25T09:45:02.369 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T10:00:00.745 OK 2025-08-25T10:05:01.242 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T10:00:01.672 OK 2025-08-25T10:05:02.371 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T10:20:00.747 OK 2025-08-25T10:25:01.244 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T10:20:01.751 OK 2025-08-25T10:25:02.373 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T10:40:00.749 OK 2025-08-25T10:45:01.246 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T10:40:01.754 OK 2025-08-25T10:45:02.375 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T11:00:00.752 OK 2025-08-25T11:05:01.248 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T11:00:01.756 OK 2025-08-25T11:05:02.378 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T11:20:00.754 OK 2025-08-25T11:25:01.251 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T11:20:01.758 OK 2025-08-25T11:25:02.380 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T11:40:00.755 OK 2025-08-25T11:45:01.253 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T11:40:01.759 OK 2025-08-25T11:45:02.382 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T11:54:00.752 OK 2025-08-25T11:54:00.752 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2025-08-25T12:01:00.753 OK 2025-08-25T12:01:00.753 OK 50 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-08-25T12:01:02.753 OK 2025-08-25T12:01:02.753 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2025-08-25T12:01:03.753 OK 2025-08-25T12:01:03.753 OK 6 TC(200,134) ZIA58707 SWA TC report configuration parameters 2025-08-25T12:02:20.762 OK 2025-08-25T12:02:20.763 OK 2 TC(203,158) ZIA58944 SWA TC PAS stop science 2025-08-25T12:02:30.763 OK 2025-08-25T12:11:20.015 OK 22 TC(203,128) ZIA58850 SWA TC PAS enter in Calibration mode 2025-08-25T12:12:30.754 OK 2025-08-25T12:12:30.755 OK 50 TC(200,133) ZIA58706 SWA TC modify the configuration parameters 2025-08-25T12:12:32.754 OK 2025-08-25T12:12:32.754 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change 2025-08-25T12:12:33.754 OK 2025-08-25T12:12:33.754 OK 6 TC(200,134) ZIA58707 SWA TC report configuration parameters 2025-08-25T12:12:40.754 OK 2025-08-25T12:12:40.754 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2025-08-25T12:30:00.785 OK 2025-08-25T12:35:01.259 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T12:30:01.765 OK 2025-08-25T12:35:02.388 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T13:00:00.765 OK 2025-08-25T13:05:01.262 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T13:00:01.769 OK 2025-08-25T13:05:02.391 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T13:20:00.654 OK 2025-08-25T13:25:01.264 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T13:20:01.672 OK 2025-08-25T13:25:02.393 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T13:40:00.658 OK 2025-08-25T13:45:01.266 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T13:40:01.674 OK 2025-08-25T13:45:02.396 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T14:00:00.658 OK 2025-08-25T14:05:01.269 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T14:00:01.677 OK 2025-08-25T14:05:02.398 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T14:20:00.663 OK 2025-08-25T14:25:01.271 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T14:20:01.679 OK 2025-08-25T14:25:02.424 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T14:40:00.664 OK 2025-08-25T14:45:01.273 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T14:40:01.681 OK 2025-08-25T14:45:02.402 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T15:00:00.665 OK 2025-08-25T15:00:00.665 ERR 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T15:00:01.683 OK 2025-08-25T15:00:01.684 ERR 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T15:20:00.667 OK 2025-08-25T15:25:01.278 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T15:20:01.688 OK 2025-08-25T15:25:02.407 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T15:40:00.671 OK 2025-08-25T15:45:01.280 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T15:40:01.688 OK 2025-08-25T15:45:02.409 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T16:00:00.671 OK 2025-08-25T16:05:01.282 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T16:00:01.690 OK 2025-08-25T16:05:02.411 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T16:20:00.674 OK 2025-08-25T16:25:01.284 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T16:20:01.692 OK 2025-08-25T16:25:02.413 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T16:40:00.678 OK 2025-08-25T16:40:00.678 ERR 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T16:40:01.695 OK 2025-08-25T16:40:01.695 ERR 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T17:00:00.678 OK 2025-08-25T17:05:01.312 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T17:00:01.697 OK 2025-08-25T17:05:02.418 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T17:19:00.661 OK 2025-08-25T17:19:00.661 OK 2 TC(200,146) ZIA58719 SWA TC disable RPW Trigger handling 2025-08-25T17:25:00.662 OK 2025-08-25T17:25:01.162 OK 20 TC(200,160) ZIA58726 SWA TC enter all sensor in Burst Mode 2025-08-25T17:40:00.663 OK 2025-08-25T17:40:00.664 OK 6 TC(200,145) ZIA58718 SWA TC enable RPW Trigger handling 2025-08-25T18:00:00.685 OK 2025-08-25T18:05:01.295 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T18:00:01.704 OK 2025-08-25T18:05:02.425 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T18:20:00.687 OK 2025-08-25T18:25:01.298 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T18:20:01.706 OK 2025-08-25T18:25:02.427 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T18:40:00.691 OK 2025-08-25T18:45:01.300 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T18:40:01.708 OK 2025-08-25T18:45:02.429 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T19:00:00.692 OK 2025-08-25T19:05:01.302 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T19:00:01.712 OK 2025-08-25T19:05:02.431 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T19:20:00.694 OK 2025-08-25T19:25:01.304 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T19:20:01.713 OK 2025-08-25T19:25:02.433 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T19:40:00.698 OK 2025-08-25T19:45:01.307 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T19:40:01.715 OK 2025-08-25T19:45:02.436 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T20:00:00.698 OK 2025-08-25T20:05:01.309 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T20:00:01.717 OK 2025-08-25T20:05:02.438 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T20:20:00.701 OK 2025-08-25T20:25:01.311 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T20:20:01.719 OK 2025-08-25T20:25:02.440 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T20:40:00.704 OK 2025-08-25T20:45:01.313 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T20:40:01.721 OK 2025-08-25T20:45:02.442 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T21:00:00.705 OK 2025-08-25T21:00:00.705 ERR 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T21:00:01.724 OK 2025-08-25T21:00:01.724 ERR 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T21:20:00.707 OK 2025-08-25T21:25:01.318 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T21:20:01.726 OK 2025-08-25T21:25:02.447 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T21:40:00.713 OK 2025-08-25T21:45:01.320 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T21:40:01.728 OK 2025-08-25T21:45:02.449 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T22:00:00.712 OK 2025-08-25T22:05:01.322 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T22:00:01.730 OK 2025-08-25T22:05:02.451 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T22:20:00.714 OK 2025-08-25T22:25:01.324 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T22:20:01.733 OK 2025-08-25T22:25:02.454 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T22:40:00.718 OK 2025-08-25T22:45:01.327 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T22:40:01.737 OK 2025-08-25T22:45:02.456 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T23:00:00.718 OK 2025-08-25T23:05:01.329 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T23:00:01.737 OK 2025-08-25T23:05:02.458 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T23:20:00.721 OK 2025-08-25T23:25:01.331 OK 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T23:20:01.739 OK 2025-08-25T23:25:02.460 OK 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode 2025-08-25T23:40:00.748 OK 2025-08-25T23:40:00.748 ERR 4 TC(201,164) ZIA58788 SWA TC EAS1 enter in engineering 2 mode 2025-08-25T23:40:01.741 OK 2025-08-25T23:40:01.742 ERR 4 TC(202,164) ZIA58836 SWA TC EAS2 enter in engineering 2 mode Number of TC = 208 Number of TARS = 208 Number of TARF = 0 Number of TECS = 196 Number of TECF = 12 Number unacked = 0 Unknown TARF = 0 Unknown TECF = 0 Dupicate TARSF = 35 Dupicate TECSF = 37