History
2023/05/13 PAS/EAS recovery
PAS and EAS have been recovered on 2023/05/13, but in SAFE mode (HV down) before week-end.
They should have been restarted in science mode by normal MTL commanding of STP 258 on next monday.
2023/05/15 THF event during WOL
PAS and EAS should have been restarted in science mode, with STP 258 MTL IOR.
We received a THF event on 2023/05/15 01:05 during the WOL at start of each STP period.
APID ( 99, 7) TM ( 5, 1) SEQ (00265,3) Size = 4 2023-05-15T01:05:00.167 : SID 43550 : SWA_E_PLATFORM_EVENT
APID ( 99, 7) TM ( 5, 2) SEQ (00266,3) Size = 14 2023-05-15T01:05:00.169 : SID 43648 : SWA_E_THFIRE_TC20_EVNT
APID ( 99, 7) TM ( 5, 1) SEQ (00267,3) Size = 6 2023-05-15T01:05:45.542 : SID 43559 : SWA_E_RECOVERY_TERMINATED
See complete log:
Missing command in SWA recovery PDOR to disable PAS/EAS reaction to Thruster Fire
Result was to put PAS and EAS OFF
2023/05/16 SWA PDOR recovery
A PDOR has been send to restart PAS and EAS in normal mode
The recovery PDOR:
Full PDOR (xml version):
TC failures and events
The corresponding commanding was:
2023-05-16T16:00:10.661 OK 2023-05-16T16:00:10.662 OK 4 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters
2023-05-16T16:00:15.661 OK 2023-05-16T16:00:15.661 OK 4 TC(200,165) ZIA58004 SWA TC enable/disable command to individual sensor
2023-05-16T16:00:20.661 OK 2023-05-16T16:00:20.662 OK 4 TC(200,176) ZIA58069 SWA TC reset the ERROR condition counters for the spec. Event
2023-05-16T16:00:25.661 OK 2023-05-16T16:00:25.662 OK 4 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters
2023-05-16T16:00:30.661 OK 2023-05-16T16:00:30.661 OK 50 TC(200,133) ZIA58706 SWA TC modify the configuration parameters
2023-05-16T16:00:32.661 OK 2023-05-16T16:00:32.661 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change
2023-05-16T16:00:33.661 OK 2023-05-16T16:00:33.661 OK 6 TC(200,134) ZIA58707 SWA TC report configuration parameters
2023-05-16T16:00:35.661 OK 2023-05-16T16:00:35.661 OK 38 TC(200,133) ZIA58706 SWA TC modify the configuration parameters
2023-05-16T16:00:37.661 OK 2023-05-16T16:00:37.661 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change
2023-05-16T16:00:38.661 OK 2023-05-16T16:00:38.661 OK 6 TC(200,134) ZIA58707 SWA TC report configuration parameters
2023-05-16T16:00:40.661 OK 2023-05-16T16:00:40.661 OK 38 TC(200,133) ZIA58706 SWA TC modify the configuration parameters
2023-05-16T16:00:42.661 OK 2023-05-16T16:00:42.661 OK 2 TC(200,135) ZIA58708 SWA TC accept configuration parameters change
2023-05-16T16:00:43.661 OK 2023-05-16T16:00:43.661 OK 6 TC(200,134) ZIA58707 SWA TC report configuration parameters
2023-05-16T16:00:45.661 OK 2023-05-16T16:00:45.662 OK 4 TC( 3, 5) ZIA58050 SWA TC enable HK report generation
2023-05-16T16:00:46.561 OK 2023-05-16T16:00:46.562 OK 31 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters
# Start of AIAF016A
2023-05-16T16:00:48.661 OK 2023-05-16T16:00:51.286 OK 2 TC(203,136) ZIA58858 PAS Power ON
2023-05-16T16:01:48.662 OK 2023-05-16T16:01:48.662 OK 6 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters
2023-05-16T16:02:18.662 OK 2023-05-16T16:02:18.662 OK 4 TC(200,171) ZIA58064 SWA TC disable the monitoring of parameters
2023-05-16T16:02:19.662 OK 2023-05-16T16:02:19.662 OK 4 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters
2023-05-16T16:02:20.661 ERR -- 4 TC(203,159) ZIA58947 SWA TC PAS set open loop
2023-05-16T16:02:25.661 ERR -- 2 TC(203,131) ZIA58853 SWA TC PAS config
2023-05-16T16:13:25.663 OK 2023-05-16T16:13:25.663 OK 5 TC(200,170) ZIA58063 SWA TC enable the monitoring of parameters
2023-05-16T16:13:55.663 ERR -- 6 TC(203,141) ZIA58863 SWA TC PAS write Master Control register
2023-05-16T16:14:00.663 ERR -- 6 TC(203,141) ZIA58863 SWA TC PAS write Master Control register
2023-05-16T16:14:05.663 ERR -- 4 TC(203,140) ZIA58862 SWA TC PAS write Pre-Amp power Control register
2023-05-16T16:14:10.663 ERR -- 24 TC(203,154) ZIA58876 SWA TC PAS Upload Static Table
2023-05-16T16:14:15.663 ERR -- 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control
2023-05-16T16:14:45.663 ERR -- 6 TC(203,151) ZIA58873 SWA TC PAS Write Mailbox control
2023-05-16T16:14:50.663 ERR -- 10 TC(203,134) ZIA58856 PAS HV Ramp UP
We received a new event SWA_E_PAS_EM_OFF on 2023/05/16 16:01:58
APID ( 99, 7) TM ( 5, 2) SEQ (00268,3) Size = 14 2023-05-16T16:01:58.037 : SID 43650 : SWA_E_PAS_EM_OFF
APID ( 99, 7) TM ( 5, 1) SEQ (00269,3) Size = 6 2023-05-16T16:02:08.161 : SID 43559 : SWA_E_RECOVERY_TERMINATED
Complete log:
The PAS_EM_OFF event was received during execution of PAS power on sequence AIAF016A.
It’s a normal behaviour in case DPU don’t receive any PAS HK/science packet during a period > N seconds (32 ?)
It’s a monitored parameter, that trigger a PAS SPW HeartBeat error code
APID ( 99, 7) TM ( 5, 2) SEQ (00268,3) Size = 14 2023-05-16T16:01:58.037 : SID 43650 : SWA_E_PAS_EM_OFF
Type : Error/anomaly : LOW severity
0000 : AA 82 00 03 00 00 00 2D 02 1A 00 00 00 20
---
EventId = AA82 : SWA_E_PAS_EM_OFF
Error = 3 : PAR_GREATER
Recovery = 0 : None (SUCCESSFULL)
MontorId = 45 : PASSPWHB_MI
ParValue = 538 : must be in [0, 32]
PAS HK packet content
The following logfile contains the detail of PAS HK packet data content (without CCSDS header) starting 2013/05/16 15:55 (just before SWA receovery at 16:00).
The first PAS HK packets are a copy of the latest HK received just before the THF event, that conduce to put PAS and EAS OFF.
Then, starting 16:00:56, all PAK HK contains 0 values, including coarse/fine time stamps ⇒ 0 correspond to time origin 2020-01-01T00:00:00